LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2024 >> TX 350 Base, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 116 (Heating / Air Conditioning System - Diagnostic Codes (2 Of 3)) >> AIR CONDITIONING SYSTEM (for PHEV Model) >> DTC P0534-7A: Refrigerant Gas Fluid Leak or Seal Failure [12/2023 - ] >> Description

DTC P0534-7A: Refrigerant Gas Fluid Leak or Seal Failure [12/2023 - ]: Description

WARNING: This page is about a different car, the 2024 Lexus TX 550h+. However, it is still accessible from the selected car via links, so may be relevant.

This DTC is stored if the amount of refrigerant in the air conditioning system is insufficient.

The air conditioning amplifier assembly receives the ambient temperature signal, refrigerant pressure signal, etc. from various sensors.

Based on these signals, the air conditioning amplifier assembly detects the amount of refrigerant.

The A/C switch indicator is turned off and the air conditioning system is stopped if the amount of refrigerant is insufficient.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory DTC Output from Priority Note
P0534-7A Refrigerant Gas Fluid Leak or Seal Failure Diagnosis Condition:
  1. Normal operation refrigerant amount check conditions are met.

    The following condition is detected in the normal operation refrigerant shortage check


Malfunction:
  1. Amount of refrigerant is judged to be insufficient by normal operation refrigerant amount check.

    Amount of refrigerant is insufficient


Detection Time:
  1. Air conditioning system operating time: 15 minutes or more
  • Refrigerant volume
  • Air conditioning pressure sensor
  • Harness or connector
  • Air conditioning amplifier assembly
Does not come on Memorized Air Conditioner A -