DTC P0070-11: Ambient Temperature Sensor Circuit Short to Ground [12/2023 - ]: Procedure
WARNING: This page is about a different car, the 2024 Lexus TX 550h+. However, it is still accessible from the selected car via links, so may be relevant.
- CLEAR DTC
Result:
NEXT
See step 2
- CHECK FOR DTC
Pre-procedure1
- Turn the ignition switch off.
- Disconnect the ambient temp. sensor (thermistor assembly) connector.
*1 Ambient Temp. Sensor (Thermistor Assembly) *2 Air Conditioning Amplifier Assembly - Turn the ignition switch to ON and wait for 4 seconds or more.
- Check for DTCs.
Body Electrical > Air Conditioner > Trouble Codes
Result
Result Proceed to P0070-15 is output A P0070-11 is output B
Post-procedure1
- None
Result:
A
REPLACE AMBIENT TEMP. SENSOR (THERMISTOR ASSEMBLY). Refer to REMOVAL [12/2023 - ]
Result:
B
See step 3
- CHECK HARNESS AND CONNECTOR (AMBIENT TEMP. SENSOR (THERMISTOR ASSEMBLY) - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Pre-procedure1
- Disconnect the B13 ambient temp. sensor (thermistor assembly) connector.
- Disconnect the D35 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Result B13-1 (+) or D35-1 (TAM) - Other terminals and body ground Always 10 kΩ or higher kΩ B13-2 (-) or D35-14 (SG-2) - Other terminals and body ground Always 10 kΩ or higher kΩ Result
Proceed to OK NG
Post-procedure1
- None
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [09/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR