LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2024 >> TX 350 Base, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 116 (Heating / Air Conditioning System - Diagnostic Codes (2 Of 3)) >> AIR CONDITIONING SYSTEM (for PHEV Model) >> DTC P0070-11: Ambient Temperature Sensor Circuit Short to Ground [12/2023 - ] >> Procedure

DTC P0070-11: Ambient Temperature Sensor Circuit Short to Ground [12/2023 - ]: Procedure

WARNING: This page is about a different car, the 2024 Lexus TX 550h+. However, it is still accessible from the selected car via links, so may be relevant.
  1. CLEAR DTC 
    1. Clear the DTCs.

      Body Electrical > Air Conditioner > Clear DTCs 

      Result

      Proceed to
      NEXT

    Result: 

    NEXT 

    See step  2

  2. CHECK FOR DTC 

    Pre-procedure1

    • Turn the ignition switch off.
    • Disconnect the ambient temp. sensor (thermistor assembly) connector.
      GTY1235899Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *1 Ambient Temp. Sensor (Thermistor Assembly)
      *2 Air Conditioning Amplifier Assembly
    • Turn the ignition switch to ON and wait for 4 seconds or more.
    • Check for DTCs.

      Body Electrical > Air Conditioner > Trouble Codes 

      Result

      Result Proceed to
      P0070-15 is output A
      P0070-11 is output B

    Post-procedure1

    • None

    Result: 

    REPLACE AMBIENT TEMP. SENSOR (THERMISTOR ASSEMBLY). Refer to  REMOVAL [12/2023 - ] 

    Result: 

    See step  3

  3. CHECK HARNESS AND CONNECTOR (AMBIENT TEMP. SENSOR (THERMISTOR ASSEMBLY) - AIR CONDITIONING AMPLIFIER ASSEMBLY) 

    Pre-procedure1

    • Disconnect the B13 ambient temp. sensor (thermistor assembly) connector.
    • Disconnect the D35 air conditioning amplifier assembly connector.
    • Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition Result
      B13-1 (+) or D35-1 (TAM) - Other terminals and body ground Always 10 kΩ or higher
      B13-2 (-) or D35-14 (SG-2) - Other terminals and body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Post-procedure1

    • None

    Result: 

    OK 

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to  REMOVAL [09/2023 - ] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR