DTC B147D-15: Rear Right Room Temperature Sensor Circuit Short to Battery or Open [12/2023 - ]: Procedure
WARNING: This page is about a different car, the 2024 Lexus TX 550h+. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK NO. 2 ROOM TEMP. SENSOR (COOLER THERMISTOR) CIRCUIT
Pre-procedure1
- Disconnect the I8 No. 2 room temp. sensor (cooler thermistor) connector.
*a Front view of wire harness connector
(to No. 2 Room Temp. Sensor (Cooler Thermistor))
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition Result I8-1 (+) - Body ground Ignition switch ON 0 to 5.5 V V Result
Proceed to OK NG
Post-procedure1
- None
Result:
NG
See step 5
Result:
OK
See step 2
- Disconnect the I8 No. 2 room temp. sensor (cooler thermistor) connector.
- CLEAR DTC
Result:
NEXT
See step 3
- CHECK FOR DTC
Pre-procedure1
- Turn the ignition switch off.
- Disconnect the I8 No. 2 room temp. sensor (cooler thermistor) connector.
*a Front view of wire harness connector
(to No. 2 Room Temp. Sensor (Cooler Thermistor)) - Connect terminals 1 and 2 of the No. 2 room temp. sensor (cooler thermistor) connector on the wire harness side.
*1 No. 2 Room Temp. Sensor (Cooler Thermistor) *2 Air Conditioning Amplifier Assembly - Turn the ignition switch to ON and wait for 4 seconds or more.
- Check for DTCs.
Body Electrical > Air Conditioner > Trouble Codes
Result
Result Proceed to B147D-11 is output A B147D-15 is output B
Post-procedure1
- None
Result:
A
REPLACE NO. 2 ROOM TEMP. SENSOR (COOLER THERMISTOR). Refer to REMOVAL [09/2023 - ]
Result:
B
See step 4
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - NO. 2 ROOM TEMP. SENSOR (COOLER THERMISTOR))
Pre-procedure1
- Disconnect the I8 No. 2 room temp. sensor (cooler thermistor) connector.
- Disconnect the D37 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Result I8-1 (+) - D37-8 (RRTR) Always Below 1 Ω Ω I8-2 (-) - D37-14 (SG-8) Always Below 1 Ω Ω Result
Proceed to OK NG
Post-procedure1
- None
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [09/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - NO. 2 ROOM TEMP. SENSOR (COOLER THERMISTOR))
Pre-procedure1
- Disconnect the I8 No. 2 room temp. sensor (cooler thermistor) connector.
- Disconnect the D37 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Result I8-1 (+) or D37-8 (RRTR) - Other terminals and body ground Always 10 kΩ or higher kΩ Result
Proceed to OK NG
Post-procedure1
- None
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [09/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR