DTC B1511-87: Lost Communication with Meter Gigabit Video Interface Missing Message [09/2023 - ]: Procedure
- CHECK HARNESS AND CONNECTOR (METER MIRROR SUB-ASSEMBLY - COMBINATION METER ASSEMBLY)
Pre-procedure1
- Disconnect the D98 meter mirror sub-assembly connector.
- Disconnect the D97 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Result D98-1 (MGV+) - D97-2 (HGV+) Always Below 1 Ω Ω D98-2 (MGV-) - D97-1 (HGV-) Always Below 1 Ω Ω D98-3 (MGVG) - D97-3 (HGVG) Always Below 1 Ω Ω D98-1 (MGV+) or D97-2 (HGV+) - Body ground Always 10 kΩ or higher kΩ D98-2 (MGV-) or D97-1 (HGV-) - Body ground Always 10 kΩ or higher kΩ Result
Proceed to OK NG
Post-procedure1
- None
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 2
- REPLACE METER MIRROR SUB-ASSEMBLY
- Replace the meter mirror sub-assembly with a new or known good one.
HINT:
Refer to REMOVAL [09/2023 - ]
Result
Proceed to NEXT
Result:
NEXT
See step 3
- Replace the meter mirror sub-assembly with a new or known good one.
- CLEAR DTC
Result:
NEXT
See step 4
- CHECK FOR DTC
- Check for DTCs.
Body Electrical > Combination Meter > Trouble Codes
Result
Result Proceed to B1511-87 is not output A B1511-87 is output B
Result:
A
END (METER MIRROR SUB-ASSEMBLY IS DEFECTIVE)
Result:
B
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [09/2023 - ]
- Check for DTCs.