Installation [10/2022 - 08/2023]: Procedure
- INSTALL AUXILIARY BATTERY
- INSTALL BATTERY CLAMP SUB-ASSEMBLY
Bolt
Torque: 5.4 N.m (55 kgf/cm, 48 in.lbf)
Nut
Torque: 5.4 N.m (55 kgf/cm, 48 in.lbf)
- INSTALL BATTERY HOSE NOTE:HINT:
After replacing the auxiliary battery, install the ventilation hole plug supplied with the new auxiliary battery or the ventilation hole plug from the old auxiliary battery to the ventilation hole on the side to which the battery hose is not connected.
- Push the battery hose onto the auxiliary battery until a click sound is heard.
- Do not twist the battery hose.
- CONNECT CABLE TO POSITIVE AUXILIARY BATTERY TERMINAL
Torque: 5.4 N.m (55 kgf/cm, 48 in.lbf)
- CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL
Torque: 5.4 N.m (55 kgf/cm, 48 in.lbf)
- INSTALL BATTERY SERVICE COVER PLATE
- INITIALIZATION AFTER RECONNECTING AUXILIARY BATTERY TERMINAL
Refer to WORK PROCEDURE [10/2022 - ]
HINT:
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.