DTC B2291-7E: Sub Battery System Output Power Relay "D" Actuator Stuck On [08/2023 - ]: Procedure
- CHECK FOR DTC
- Check for DTCs.
Body Electrical > Sub Battery System > Trouble Codes
Result
Result Proceed to B2291-7E is output A B2291-7E is not output B
Result:
B
USE SIMULATION METHOD TO CHECK. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [10/2022 - ]
Result:
A
See step 2
- Check for DTCs.
- CHECK HARNESS AND CONNECTOR (INTEGRATION CONTROL SUPPLY - FRONT DOOR LOCK WITH MOTOR ASSEMBLY LH, RH AND REAR DOOR LOCK WITH MOTOR ASSEMBLY LH, RH)
Pre-procedure1
- Disconnect the H191 integrated capacitor (integration control supply) connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition Result H191-20 (BUA2) - Body ground Ignition switch off Below 5 V V Result
Proceed to OK NG
Post-procedure1
- None
Result:
OK
REPLACE INTEGRATED CAPACITOR (INTEGRATION CONTROL SUPPLY). Refer to REMOVAL [08/2023 - ]
Result:
NG
See step 3
- CHECK HARNESS AND CONNECTOR (INTEGRATED CAPACITOR (INTEGRATION CONTROL SUPPLY) - FRONT DOOR LOCK WITH MOTOR ASSEMBLY LH)
Pre-procedure1
- Disconnect the D34 front door lock with motor assembly LH connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition Result H191-20 (BUA2) - Body ground Ignition switch off Below 1 V V Result
Proceed to OK NG
Post-procedure1
- None
Result:
OK
REPLACE FRONT DOOR LOCK WITH MOTOR ASSEMBLY LH. Refer to REMOVAL [08/2023 - ]
Result:
NG
See step 4
- CHECK HARNESS AND CONNECTOR (INTEGRATED CAPACITOR (INTEGRATION CONTROL SUPPLY) - FRONT DOOR LOCK WITH MOTOR ASSEMBLY RH)
Pre-procedure1
- Disconnect the D15 front door lock with motor assembly RH connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition Result H191-20 (BUA2) - Body ground Ignition switch off Below 1 V V Result
Proceed to OK NG
Post-procedure1
- None
Result:
OK
REPLACE FRONT DOOR LOCK WITH MOTOR ASSEMBLY RH. Refer to REMOVAL [08/2023 - ]
Result:
NG
See step 5
- CHECK HARNESS AND CONNECTOR (INTEGRATED CAPACITOR (INTEGRATION CONTROL SUPPLY) - REAR DOOR LOCK WITH MOTOR ASSEMBLY LH)
Pre-procedure1
- Disconnect the E16 rear door lock with motor assembly LH connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition Result H191-20 (BUA2) - Body ground Ignition switch off Below 1 V V Result
Proceed to OK NG
Post-procedure1
- None
Result:
OK
REPLACE REAR DOOR LOCK WITH MOTOR ASSEMBLY LH. Refer to REMOVAL [08/2023 - ]
Result:
NG
See step 6
- CHECK HARNESS AND CONNECTOR (INTEGRATED CAPACITOR (INTEGRATION CONTROL SUPPLY) - REAR DOOR LOCK WITH MOTOR ASSEMBLY RH)
Pre-procedure1
- Disconnect the E6 rear door lock with motor assembly RH connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition Result H191-20 (BUA2) - Body ground Ignition switch off Below 1 V V Result
Proceed to OK NG
Post-procedure1
- None
Result:
OK
REPLACE REAR DOOR LOCK WITH MOTOR ASSEMBLY RH. Refer to REMOVAL [08/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR