No Cooling at All [08/2023 - ]: Procedure
- CHECK RADIO AND DISPLAY RECEIVER ASSEMBLY (SWITCH INDICATOR)
- Operate each switch on the radio and display receiver assembly to check that the switch indicators are illuminated normally.
OK
Switch indicators are illuminated normally.
Result
Proceed to OK NG
Result:
NG
GO TO OTHER DIAGNOSIS PROCEDURE (A/C Switch Indicator does not Turn On). Refer to A/C Switch Indicator does not Turn On [08/2023 - ]
Result:
OK
See step 2
- Operate each switch on the radio and display receiver assembly to check that the switch indicators are illuminated normally.
- CHECK REFRIGERANT SHORTAGE
- Prepare the vehicle according to the table below.MEASUREMENT CONDITION:
Item Condition A/C Switch On Ambient Temperature*1 0 to 49°C (32 to 120°F) Air Conditioning Air Inlet Temperature*2 25 to 35°C (77 to 95°F) Set Temperature MAX COLD Recirculation/fresh Control Switch Recirculation Air Vent Damper Position FACE Blower Speed HI HINT:
*1: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.
*2: This inspection can be judged correctly only if the air inlet temperature is within a range of 25 to 35°C (77 to 95°F). Therefore, postpone the test if the temperature is out of range.
- Using the GTS, check the amount of refrigerant.
Body Electrical > Air Conditioner > Utility
Tester Display Refrigerant Gas Volume Check NOTE:If the conditions for the inspection are not met, "Refrigerant incorrect" will be displayed on the GTS. Confirm the conditions of the inspection and perform the check again.
HINT:
- If the amount of refrigerant is insufficient, "Refrigerant shortage" is displayed on the GTS and the indicator light on the A/C switch turns off.
- When performing this inspection, a DTC will not be output even if "Refrigerant shortage" is displayed on the GTS.
Result
Result Amount of Refrigerant Refrigerant shortage Insufficient or leakage Refrigerant correct Correct Refrigerant incorrect Incorrect OK
"Refrigerant correct" is displayed on the GTS.
Result
Proceed to OK NG
Result:
NG
CHARGE SYSTEM WITH REFRIGERANT. Refer to REPLACEMENT [08/2023 - ]
Result:
OK
See step 3
- Prepare the vehicle according to the table below.
- PERFORM ACTIVE TEST USING GTS
- Perform the Active Test according to the display on the GTS.
Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Front Left Air Mix Damper Control Servo Motor This test activates the Front Left Air Mix Damper Control Servo Motor.
(No. 1 air conditioning radiator damper servo sub-assembly (front left side air mix))128: Min
384: MaxOperate with ignition switch ON. Front Right Air Mix Damper Control Servo Motor This test activates the Front Right Air Mix Damper Control Servo Motor.
(No. 1 air conditioning radiator damper servo sub-assembly (front right side air mix))128: Min
384: MaxOperate with ignition switch ON. Fr Control Rear Air Mix Damper Control Servo Motor This test activates the Front Control Rear Air Mix Damper Control Servo Motor.
(No. 4 air conditioning radiator damper servo sub-assembly (rear air mix))128: Min
384: MaxOperate with ignition switch ON. Body Electrical > Air Conditioner > Active Test
Active Test Display Front Left Air Mix Damper Control Servo Motor Data List Display Front Left Air Mix Damper Control Servo Motor Actual Pulse Body Electrical > Air Conditioner > Active Test
Active Test Display Front Right Air Mix Damper Control Servo Motor Data List Display Front Right Air Mix Damper Control Servo Motor Actual Pulse Body Electrical > Air Conditioner > Active Test
Active Test Display Fr Control Rear Air Mix Damper Control Servo Motor Data List Display Front Control Rear Air Mix Damper Control Servo Motor Actual Pulse OK
Damper servo motor is operated.
Result
Proceed to OK NG
Result:
NG
GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR. Refer to DIAGNOSTIC TROUBLE CODE CHART [08/2023 - ]
Result:
OK
See step 4
- Perform the Active Test according to the display on the GTS.
- CHECK DTC
- Check for DTCs.
Body Electrical > Air Conditioner > Trouble Codes
OK
DTC B13AE-7F, B144C-7F and B145B-7F are not output
Result
Proceed to OK NG
Result:
NG
GO TO DIAGNOSTIC TROUBLE CODE CHART. Refer to DIAGNOSTIC TROUBLE CODE CHART [08/2023 - ]
Result:
OK
See step 5
- Check for DTCs.
- CHECK PROBLEM SYMPTOMS
- Check the vehicle condition.
Result
Result Proceed to Compressor is operating, but does not cool A Operation is stopped due to a high pressure cut B
Result:
B
See step 15
Result:
A
See step 6
- Check the vehicle condition.
- CHECK COOLING ELECTRIC EXPANSION VALVE (COOLER EXPANSION VALVE)
- Set the vehicle to the following conditions.MEASUREMENT CONDITION:
Item Condition Vehicle Condition Ignition switch ON (READY) A/C Switch On Ambient Temperature* 0 to 49°C (32 to 120°F) Set Temperature MAX COLD Recirculation/fresh Control Switch Recirculation Air Vent Damper Position FACE Blower Speed HI HINT:
*: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.
- Using the GTS, perform the Active Test and check the Data List values.
Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Cooling Electric Expansion Valve Operation of the cooler expansion valve Min.: 0%
Max.: 100%Perform within the range of 20 to 38% (display range is 0 to 100%) Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Evaporator Fin Thermistor Evaporator temp. sensor (No. 1 cooler thermistor) -327.68 to 327.67°C Actual evaporator temperature displayed Evaporator temp. sensor (No. 1 cooler thermistor) circuit malfunction Regulator Pressure Sensor Air conditioning pressure sensor -32768 to 32767 kPa(gauge) (-32.768 to 32.767 MPaG) Actual refrigerant pressure displayed - Refrigerant line (gas leak etc.)
- Air conditioning pressure sensor circuit malfunction
Compressor Actual Speed Compressor speed 0 to 10000 rpm Actual compressor speed displayed When compressor running: - Compressor with motor assembly
Cooling Electric Expansion Valve Target Position Target opening angle of cooling electric expansion valve (cooler expansion valve) 0 to 100 % Target opening angle of cooling electric expansion valve (cooler expansion valve) Cooling electric expansion valve (cooler expansion valve) circuit malfunction Subcool Target Temperature Target temperature of the sub-cooler calculated by ECU -327.68 to 327.67°C Target temperature of the sub-cooler calculated by ECU Displays in range of 0 to 30°C (32 to 86°F) Subcool Estimated Temperature (ECU Calculation Value) Sub-cooler estimated temperature calculated by ECU -327.68 to 327.67°C Sub-cooler estimated temperature calculated by ECU Displays in range of 0 to 30°C (32 to 86°F) Cooling Electric Expansion Valve Actual opening angle of cooling electric expansion valve (cooler expansion valve) 0 to 100 % Actual opening angle following the target opening angle Cooling electric expansion valve (cooler expansion valve) circuit malfunction Body Electrical > Air Conditioner > Active Test
Active Test Display Cooling Electric Expansion Valve Data List Display Evaporator Fin Thermistor Regulator Pressure Sensor Compressor Actual Speed Cooling Electric Expansion Valve Target Position Subcool Target Temperature Subcool Estimated Temperature (ECU Calculation Value) Cooling Electric Expansion Valve OK
The refrigerant pressure decreases when the control value of the cooler expansion valve is increased 20%.
The refrigerant pressure increases when the control value of the cooler expansion valve is reverted.
Result
Proceed to OK NG
Result:
NG
See step 11
Result:
OK
See step 7
- Set the vehicle to the following conditions.
- INSPECT LOW PRESSURE MAGNETIC VALVE (NO. 1 MAGNET VALVE ASSEMBLY)
Refer to INSPECTION [08/2023 - ]
Result
Proceed to OK NG Result:
NG
REPLACE LOW PRESSURE MAGNETIC VALVE (NO. 1 MAGNET VALVE ASSEMBLY). Refer to REMOVAL [08/2023 - ]
Result:
OK
See step 8
- CHECK HARNESS AND CONNECTOR (LOW PRESSURE MAGNETIC VALVE (NO. 1 MAGNET VALVE ASSEMBLY) - HEAT PUMP ECU ASSEMBLY)
- Disconnect the A57 low pressure magnetic valve (No. 1 magnet valve assembly) connector.
- Disconnect the A62 heat pump ECU assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A57-1 (LPMV) - A62-11 (LPMV) Always Below 1 Ω A57-1 (LPMV) or A62-11 (LPMV) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 9
- INSPECT HIGH PRESSURE MAGNETIC VALVE (NO. 3 MAGNET VALVE ASSEMBLY)
Refer to INSPECTION [08/2023 - ]
Result
Proceed to OK NG Result:
NG
REPLACE HIGH PRESSURE MAGNETIC VALVE (NO. 3 MAGNET VALVE ASSEMBLY). Refer to REMOVAL [08/2023 - ]
Result:
OK
See step 10
- CHECK HARNESS AND CONNECTOR (HIGH PRESSURE MAGNETIC VALVE (NO. 3 MAGNET VALVE ASSEMBLY) - HEAT PUMP ECU ASSEMBLY)
- Disconnect the A58 high pressure magnetic valve (No. 3 magnet valve assembly) connector.
- Disconnect the A62 heat pump ECU assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A58-2 (VD) - A62-10 (HPMV) Always Below 1 Ω A58-2 (VD) or A62-10 (HPMV) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE PRESSURE REGULATOR SUB-ASSEMBLY. Refer to REMOVAL [08/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- INSPECT EVAPORATOR FRONT MAGNETIC VALVE (NO. 2 MAGNET VALVE ASSEMBLY)
Refer to INSPECTION [08/2023 - ]
Result
Proceed to OK NG Result:
NG
REPLACE EVAPORATOR FRONT MAGNETIC VALVE (NO. 2 MAGNET VALVE ASSEMBLY). Refer to REMOVAL [08/2023 - ]
Result:
OK
See step 12
- CHECK HARNESS AND CONNECTOR (EVAPORATOR FRONT MAGNETIC VALVE (NO. 2 MAGNET VALVE ASSEMBLY) - HEAT PUMP ECU ASSEMBLY)
- Disconnect the A59 evaporator front magnetic valve (No. 2 magnet valve assembly) connector.
- Disconnect the A62 heat pump ECU assembly connector.
- Remove the magnet-clutch relay (A/C MG) from the No. 2 engine room relay block and No. 2 junction block assembly.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A59-2 (VC) - A62-12 (EVMV) Always Below 1 Ω Relay terminal 5 - A59-1 (VH) Always Below 1 Ω A59-2 (VC) or A62-12 (EVMV) - Body ground Always 10 kΩ or higher Relay terminal 5 or A59-1 (VH) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 13
- CHECK HARNESS AND CONNECTOR (COOLING ELECTRIC EXPANSION VALVE (COOLER EXPANSION VALVE) - HEAT PUMP ECU ASSEMBLY)
- Disconnect the q1 cooling electric expansion valve (cooler expansion valve) connector.
- Disconnect the A61 heat pump ECU assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition q1-1 (HPR-) - A61-25 (CEA2) Always Below 1 Ω q1-4 (HPR+) - A61-13 (CEA1) Always Below 1 Ω q1-5 (HPL+) - A61-14 (CEB1) Always Below 1 Ω q1-2 (HPL-) - A61-26 (CEB2) Always Below 1 Ω q1-1 (HPR-) or A61-25 (CEA2) - Other terminals and body ground Always 10 kΩ or higher q1-4 (HPR+) or A61-13 (CEA1) - Other terminals and body ground Always 10 kΩ or higher q1-5 (HPL+) or A61-14 (CEB1) - Other terminals and body ground Always 10 kΩ or higher q1-2 (HPL-) or A61-26 (CEB2) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 14
- INSPECT COOLING ELECTRIC EXPANSION VALVE (COOLER EXPANSION VALVE)
- Disconnect the q1 cooling electric expansion valve (cooler expansion valve) connector.
*a Component without harness connected
(Cooling Electric Expansion Valve (Cooler Expansion Valve)) - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 (HPR-) - 4 (HPR+) 20°C (68°F) 8 to 10 Ω 2 (HPL-) - 5 (HPL+) 20°C (68°F) 8 to 10 Ω Result
Proceed to OK NG
Result:
OK
REPLACE HEAT PUMP ECU ASSEMBLY. Refer to REMOVAL [08/2023 - ]
Result:
NG
REPLACE COOLING ELECTRIC EXPANSION VALVE (COOLER EXPANSION VALVE). Refer to REMOVAL [08/2023 - ]
- Disconnect the q1 cooling electric expansion valve (cooler expansion valve) connector.
- CHECK HEATING ELECTRIC EXPANSION VALVE (NO. 2 COOLER EXPANSION VALVE)
- Set the vehicle to the following conditions.MEASUREMENT CONDITION:
Item Condition Vehicle Condition Ignition switch ON (READY) A/C Switch On Ambient Temperature* 0 to 49°C (32 to 120°F) Set Temperature MAX COLD Recirculation/fresh Control Switch Recirculation Air Vent Damper Position FACE Blower Speed HI HINT:
*: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.
- Using the GTS, perform the Active Test and check the Data List values.
Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Heating Electric Expansion Valve This test activates heating electric expansion valve to a target position.
(Heating electric expansion valve (No. 2 cooler expansion valve))0%: Min.
100%: Max.- Ignition switch ON (READY)
- EV Mode
- Blower: Manual Hi
- Set Temperature: Manual Hi
- Ambient Temperature: -10°C (14.0°F) or more than -10°C (14.0°F)
- A/C Switch: OFF
- Air Inlet Mode: Outside Air
- Engine Coolant Temperature: 40°C (104°F) or less than 40°C (104°F)
Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Regulator Pressure Sensor Air conditioning pressure sensor -32768 to 32767 kPa(gauge) (-32.768 to 32.767 MPaG) Actual refrigerant pressure displayed - Refrigerant line (gas leak etc.)
- Air conditioning pressure sensor circuit malfunction
Front Right Air Outlet Temperature Front right side target air outlet temperature -327.68 to 327.67°C Front right side target air outlet temperature displayed - MAX COLD: -327.68°C
- MAX HOT: 327.67°C
- Front Left Air Outlet Temperature Front left side target air outlet temperature -327.68 to 327.67°C Front left side target air outlet temperature displayed - MAX COLD: -327.68°C
- MAX HOT: 327.67°C
- Front Right Set Temperature Front right side set temperature MAX COLD / 14.0°C / 14.5°C / 15.0°C / 15.5°C / 16.0°C / 16.5°C / 17.0°C / 17.5°C / 18.0°C / 18.5°C / 19.0°C / 19.5°C / 20.0°C / 20.5°C / 21.0°C / 21.5°C / 22.0°C / 22.5°C / 23.0°C / 23.5°C / 24.0°C / 24.5°C / 25.0°C / 25.5°C / 26.0°C / 26.5°C / 27.0°C / 27.5°C / 28.0°C / 28.5°C / 29.0°C / 29.5°C / 30.0°C / 30.5°C / 31.0°C / 31.5°C / 32.0°C / MAX HOT Front right side set temperature displayed Radio and display receiver assembly circuit malfunction Front Left Set Temperature Front left side set temperature MAX COLD / 14.0°C / 14.5°C / 15.0°C / 15.5°C / 16.0°C / 16.5°C / 17.0°C / 17.5°C / 18.0°C / 18.5°C / 19.0°C / 19.5°C / 20.0°C / 20.5°C / 21.0°C / 21.5°C / 22.0°C / 22.5°C / 23.0°C / 23.5°C / 24.0°C / 24.5°C / 25.0°C / 25.5°C / 26.0°C / 26.5°C / 27.0°C / 27.5°C / 28.0°C / 28.5°C / 29.0°C / 29.5°C / 30.0°C / 30.5°C / 31.0°C / 31.5°C / 32.0°C / MAX HOT Front left side set temperature displayed Radio and display receiver assembly circuit malfunction Compressor Actual Speed Compressor speed 0 to 10000 rpm Actual compressor speed displayed When compressor running: - Compressor with motor assembly
Heating Electric Expansion Valve Target Position Target opening angle of heating electric expansion valve (No. 2 cooler expansion valve) 0 to 100 % Target opening angle of heating electric expansion valve (No. 2 cooler expansion valve) Heating electric expansion valve (No. 2 cooler expansion valve) circuit malfunction Subcool Target Temperature Target temperature of the sub-cooler calculated by ECU -327.68 to 327.67°C Target temperature of the sub-cooler calculated by ECU Displays in range of 0 to 30°C (32 to 86°F) Subcool Estimated Temperature (ECU Calculation Value) Sub-cooler estimated temperature calculated by ECU -327.68 to 327.67°C Sub-cooler estimated temperature calculated by ECU Displays in range of 0 to 30°C (32 to 86°F) Heating Electric Expansion Valve Actual opening angle of heating electric expansion valve (No. 2 cooler expansion valve) 0 to 100 % Actual opening angle following the target opening angle Heating electric expansion valve (No. 2 cooler expansion valve) circuit malfunction Body Electrical > Air Conditioner > Active Test
Active Test Display Heating Electric Expansion Valve Data List Display Regulator Pressure Sensor Front Right Air Outlet Temperature Front Left Air Outlet Temperature Front Right Set Temperature Front Left Set Temperature Compressor Actual Speed Heating Electric Expansion Valve Target Position Subcool Target Temperature Subcool Estimated Temperature (ECU Calculation Value) Heating Electric Expansion Valve OK
The refrigerant pressure decreases when the control value of the No. 2 cooler expansion valve is increased 50%.
The refrigerant pressure increases when the control value of the No. 2 cooler expansion valve is reverted.
Result
Proceed to OK NG
Result:
NG
See step 19
Result:
OK
See step 16
- Set the vehicle to the following conditions.
- CHECK COOLING ELECTRIC EXPANSION VALVE (COOLER EXPANSION VALVE)
- Set the vehicle to the following conditions.MEASUREMENT CONDITION:
Item Condition Vehicle Condition Ignition switch ON (READY) A/C Switch On Ambient Temperature* 0 to 49°C (32 to 120°F) Set Temperature MAX COLD Recirculation/fresh Control Switch Recirculation Air Vent Damper Position FACE Blower Speed HI HINT:
*: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.
- Using the GTS, perform the Active Test and check the Data List values.
Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Cooling Electric Expansion Valve Operation of the cooler expansion valve Min.: 0%
Max.: 100%Perform within the range of 20 to 38% (display range is 0 to 100%) Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Evaporator Fin Thermistor Evaporator temp. sensor (No. 1 cooler thermistor) -327.68 to 327.67°C Actual evaporator temperature displayed Evaporator temp. sensor (No. 1 cooler thermistor) circuit malfunction Regulator Pressure Sensor Air conditioning pressure sensor -32768 to 32767 kPa(gauge) (-32.768 to 32.767 MPaG) Actual refrigerant pressure displayed - Refrigerant line (gas leak etc.)
- Air conditioning pressure sensor circuit malfunction
Compressor Actual Speed Compressor speed 0 to 10000 rpm Actual compressor speed displayed When compressor running: - Compressor with motor assembly
Cooling Electric Expansion Valve Target Position Target opening angle of cooling electric expansion valve (cooler expansion valve) 0 to 100 % Target opening angle of cooling electric expansion valve (cooler expansion valve) Cooling electric expansion valve (cooler expansion valve) circuit malfunction Subcool Target Temperature Target temperature of the sub-cooler calculated by ECU -327.68 to 327.67°C Target temperature of the sub-cooler calculated by ECU Displays in range of 0 to 30°C (32 to 86°F) Subcool Estimated Temperature (ECU Calculation Value) Sub-cooler estimated temperature calculated by ECU -327.68 to 327.67°C Sub-cooler estimated temperature calculated by ECU Displays in range of 0 to 30°C (32 to 86°F) Cooling Electric Expansion Valve Actual opening angle of cooling electric expansion valve (cooler expansion valve) 0 to 100 % Actual opening angle following the target opening angle Cooling electric expansion valve (cooler expansion valve) circuit malfunction Body Electrical > Air Conditioner > Active Test
Active Test Display Cooling Electric Expansion Valve Data List Display Evaporator Fin Thermistor Regulator Pressure Sensor Compressor Actual Speed Cooling Electric Expansion Valve Target Position Subcool Target Temperature Subcool Estimated Temperature (ECU Calculation Value) Cooling Electric Expansion Valve OK
The refrigerant pressure decreases when the control value of the cooler expansion valve is increased 20%.
The refrigerant pressure increases when the control value of the cooler expansion valve is reverted.
Result
Proceed to OK NG
Result:
NG
See step 11
Result:
OK
See step 17
- Set the vehicle to the following conditions.
- INSPECT HIGH PRESSURE MAGNETIC VALVE (NO. 3 MAGNET VALVE ASSEMBLY)
Refer to INSPECTION [08/2023 - ]
Result
Proceed to OK NG Result:
NG
REPLACE HIGH PRESSURE MAGNETIC VALVE (NO. 3 MAGNET VALVE ASSEMBLY). Refer to REMOVAL [08/2023 - ]
Result:
OK
See step 18
- CHECK HARNESS AND CONNECTOR (HIGH PRESSURE MAGNETIC VALVE (NO. 3 MAGNET VALVE ASSEMBLY) - HEAT PUMP ECU ASSEMBLY)
- Disconnect the A58 high pressure magnetic valve (No. 3 magnet valve assembly) connector.
- Disconnect the A62 heat pump ECU assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A58-2 (VD) - A62-10 (HPMV) Always Below 1 Ω A58-2 (VD) or A62-10 (HPMV) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE HEAT PUMP ECU ASSEMBLY. Refer to REMOVAL [08/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK HARNESS AND CONNECTOR (HEATING ELECTRIC EXPANSION VALVE (NO. 2 COOLER EXPANSION VALVE) - HEAT PUMP ECU ASSEMBLY)
- Disconnect the A56 heating electric expansion valve (No. 2 cooler expansion valve) connector.
- Disconnect the A61 heat pump ECU assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A56-1 (HV3) - A61-23 (HEA2) Always Below 1 Ω A56-4 (HV4) - A61-24 (HEA1) Always Below 1 Ω A56-5 (HV2) - A61-12 (HEB1) Always Below 1 Ω A56-2 (HV1) - A61-11 (HEB2) Always Below 1 Ω A56-1 (HV3) or A61-23 (HEA2) - Other terminals and body ground Always 10 kΩ or higher A56-4 (HV4) or A61-24 (HEA1) - Other terminals and body ground Always 10 kΩ or higher A56-5 (HV2) or A61-12 (HEB1) - Other terminals and body ground Always 10 kΩ or higher A56-2 (HV1) or A61-11(HEB2) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 20
- INSPECT HEATING ELECTRIC EXPANSION VALVE (NO. 2 COOLER EXPANSION VALVE)
- Disconnect the A56 heating electric expansion valve (No. 2 cooler expansion valve) connector.
*a Component without harness connected
(Heating Electric Expansion Valve (No. 2 Cooler Expansion Valve)) - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 (HV3) - 4 (HV4) 20°C (68°F) 8 to 10 Ω 2 (HV1) - 5 (HV2) 20°C (68°F) 8 to 10 Ω Result
Proceed to OK NG
Result:
OK
REPLACE HEAT PUMP ECU ASSEMBLY. Refer to REMOVAL [08/2023 - ]
Result:
NG
REPLACE HEATING ELECTRIC EXPANSION VALVE (NO. 2 COOLER EXPANSION VALVE). Refer to REMOVAL [08/2023 - ]
- Disconnect the A56 heating electric expansion valve (No. 2 cooler expansion valve) connector.