Home >> Lexus >> 2024 >> RX 500h >> Repair and Diagnosis >> External Pages >> Different car >> Section 83 (Heating / Air Conditioning System - Diagnostic Codes (1 Of 3)) >> AIR CONDITIONING SYSTEM (for PHEV Model) >> DTC B141A-15: Room Temperature Sensor Circuit Short to Battery or Open [08/2023 - ] >> Procedure

DTC B141A-15: Room Temperature Sensor Circuit Short to Battery or Open [08/2023 - ]: Procedure

WARNING: This page is about a different car, the 2025 Lexus RX 450h+ and 2024 Lexus RX 450h+. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK ROOM TEMP. SENSOR (COOLER THERMISTOR) CIRCUIT 

    Pre-procedure1

    • Disconnect the C57 room temp. sensor (cooler thermistor) connector.
      GTY1254203Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Front view of wire harness connector
      (to Room Temp. Sensor (Cooler Thermistor))
    • Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection Condition Specified Condition Result
      C57-1 (+) - Body ground Ignition switch ON 0 to 5.5 V V

      Result

      Proceed to
      OK
      NG

    Post-procedure1

    • None

    Result: 

    NG 

    See step  5

    Result: 

    OK 

    See step  2

  2. CLEAR DTC 
    1. Clear the DTCs.

      Body Electrical > Air Conditioner > Clear DTCs 

      Result

      Proceed to
      NEXT

    Result: 

    NEXT 

    See step  3

  3. CHECK FOR DTC 

    Pre-procedure1

    • Turn the ignition switch off.
    • Disconnect the C57 room temp. sensor (cooler thermistor) connector.
      GTY1254202Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Front view of wire harness connector
      (to Room Temp. Sensor (Cooler Thermistor))
    • Connect terminals 1 and 2 of the room temp. sensor (cooler thermistor) connector on the wire harness side.
      GTY1233137Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *1 Room Temp. Sensor (Cooler Thermistor)
      *2 Air Conditioning Amplifier Assembly
    • Turn the ignition switch to ON and wait for 4 seconds or more.
    • Check for DTCs.

      Body Electrical > Air Conditioner > Trouble Codes 

      Result

      Result Proceed to
      B141A-11 is output A
      B141A-15 is output B

    Post-procedure1

    • None

    Result: 

    REPLACE ROOM TEMP. SENSOR (COOLER THERMISTOR). Refer to  REMOVAL [10/2022 - ] 

    Result: 

    See step  4

  4. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - ROOM TEMP. SENSOR (COOLER THERMISTOR)) 

    Pre-procedure1

    • Disconnect the C57 room temp. sensor (cooler thermistor) connector.
    • Disconnect the C48 air conditioning amplifier assembly connector.
    • Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition Result
      C57-1 (+) - C48-5 (TR) Always Below 1 Ω Ω
      C57-2 (-) - C48-3 (SG-1) Always Below 1 Ω Ω

      Result

      Proceed to
      OK
      NG

    Post-procedure1

    • None

    Result: 

    OK 

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to  REMOVAL [10/2022 - ] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR 

  5. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - ROOM TEMP. SENSOR (COOLER THERMISTOR)) 

    Pre-procedure1

    • Disconnect the C57 room temp. sensor (cooler thermistor) connector.
    • Disconnect the C48 air conditioning amplifier assembly connector.
    • Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition Result
      C57-1 (+) or C48-5 (TR) - Other terminals and body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Post-procedure1

    • None

    Result: 

    OK 

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to  REMOVAL [10/2022 - ] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR