DTC B13AB-7F: Front Control Rear Air Outlet Damper Control Servo Motor Actuator Stuck Off [08/2023 - ]: Procedure
- CHECK NO. 2 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY (INSTALLATION CONDITION)
- Check that the No. 2 air conditioning radiator damper servo sub-assembly is installed correctly.
HINT:
Refer to REASSEMBLY [10/2022 - ]
OK
The No. 2 air conditioning radiator damper servo sub-assembly is installed correctly.
Result
Proceed to OK NG
Result:
NG
REINSTALL NO. 2 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY. Refer to REASSEMBLY [10/2022 - ]
Result:
OK
See step 2
- Check that the No. 2 air conditioning radiator damper servo sub-assembly is installed correctly.
- CHECK NO. 2 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY (MOTOR, LINK, DAMPER)
- Check for a wire harness caught between the links of the motors and dampers.
OK
No wire harnesses are caught between the links of the motors and dampers.
Result
Proceed to OK NG
Result:
NG
REMOVE PINCHED WIRE HARNESS
Result:
OK
See step 3
- Check for a wire harness caught between the links of the motors and dampers.
- PERFORM ACTIVE TEST USING GTS
- Perform the Active Test according to the display on the GTS.
Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Fr Control Rear Air Outlet Damper Servo Motor This test activates the rear air outlet damper control servo motor.
(No. 2 air conditioning radiator damper servo sub-assembly (rear mode))128: Min
384: MaxOperate with ignition switch ON. Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Inspection Item Front Control Rear Air Outlet Damper Control Servo Motor Actual Pulse No. 2 air conditioning radiator damper servo sub-assembly (rear mode) actual pulse 128 to 384 - FACE: 260 (pulse)
- FOOT-R, D, O, F/D: 223 (pulse)
- B/L: 212 (pulse)
- FOOT-F: 182 (pulse)
- D/F: 177 (pulse)
- DEF: 158 (pulse)
No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction Body Electrical > Air Conditioner > Active Test
Active Test Display Fr Control Rear Air Outlet Damper Servo Motor Data List Display Front Control Rear Air Outlet Damper Control Servo Motor Actual Pulse OK
The value of the Data List changes in accordance with the operation of the Active Test.
Result
Proceed to OK NG
Result:
NG
See step 7
Result:
OK
See step 4
- Perform the Active Test according to the display on the GTS.
- PERFORM ACTIVE TEST USING GTS
- Perform the Active Test according to the display on the GTS.
Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Fr Control Rear Air Outlet Damper Servo Motor This test activates the rear air outlet damper control servo motor.
(No. 2 air conditioning radiator damper servo sub-assembly (rear mode))128: Min
384: MaxOperate with ignition switch ON. Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Inspection Item Front Control Rear Air Outlet Damper Control Servo Motor Target Pulse No. 2 air conditioning radiator damper servo sub-assembly (rear mode) target pulse 128 to 384 - FACE: 260 (pulse)
- FOOT-R, D, O, F/D: 223 (pulse)
- B/L: 212 (pulse)
- FOOT-F: 182 (pulse)
- D/F: 177 (pulse)
- DEF: 158 (pulse)
No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction Front Control Rear Air Outlet Damper Control Servo Motor Actual Pulse No. 2 air conditioning radiator damper servo sub-assembly (rear mode) actual pulse 128 to 384 - FACE: 260 (pulse)
- FOOT-R, D, O, F/D: 223 (pulse)
- B/L: 212 (pulse)
- FOOT-F: 182 (pulse)
- D/F: 177 (pulse)
- DEF: 158 (pulse)
No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction Body Electrical > Air Conditioner > Active Test
Active Test Display Fr Control Rear Air Outlet Damper Servo Motor Data List Display Front Control Rear Air Outlet Damper Control Servo Motor Target Pulse Front Control Rear Air Outlet Damper Control Servo Motor Actual Pulse OK
The target pulse value of the Data List matches the actual pulse.
Result
Proceed to OK NG
Result:
OK
USE SIMULATION METHOD TO CHECK. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [10/2022 - ]
Result:
NG
See step 5
- Perform the Active Test according to the display on the GTS.
- REPLACE NO. 2 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY
HINT:
Refer to DISASSEMBLY [10/2022 - ]
Result
Proceed to NEXT Result:
NEXT
See step 6
- PERFORM ACTIVE TEST USING GTS
- Perform the Active Test according to the display on the GTS.
Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Fr Control Rear Air Outlet Damper Servo Motor This test activates the rear air outlet damper control servo motor.
(No. 2 air conditioning radiator damper servo sub-assembly (rear mode))128: Min
384: MaxOperate with ignition switch ON. Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Inspection Item Front Control Rear Air Outlet Damper Control Servo Motor Actual Pulse No. 2 air conditioning radiator damper servo sub-assembly (rear mode) actual pulse 128 to 384 - FACE: 260 (pulse)
- FOOT-R, D, O, F/D: 223 (pulse)
- B/L: 212 (pulse)
- FOOT-F: 182 (pulse)
- D/F: 177 (pulse)
- DEF: 158 (pulse)
No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction Body Electrical > Air Conditioner > Active Test
Active Test Display Fr Control Rear Air Outlet Damper Servo Motor Data List Display Front Control Rear Air Outlet Damper Control Servo Motor Actual Pulse OK
The value of the Data List changes in accordance with the operation of the Active Test.
Result
Proceed to OK NG
Result:
OK
END
Result:
NG
REPLACE AIR CONDITIONING HARNESS ASSEMBLY. Refer to DISASSEMBLY [10/2022 - ]
- Perform the Active Test according to the display on the GTS.
- PERFORM ACTIVE TEST USING GTS
- Perform the Active Test according to the display on the GTS.
Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Front Air Outlet Damper Control Servo Motor This test activates the front air outlet damper control servo motor.
(No. 1 air conditioning radiator damper servo sub-assembly (front mode))128: Min
384: MaxOperate with the ignition switch ON. Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Inspection Item Front Air Outlet Damper Control Servo Motor Actual Pulse No. 1 air conditioning radiator damper servo sub-assembly (front mode) actual pulse 128 to 384 - FACE: 256 (pulse)
- B/L: 267 (pulse)
- FOOT-A: 288 (pulse)
- FOOT-R (F): 297 (pulse)
- FOOT-D: 305 (pulse)
- F/D-R: 320 (pulse)
- D/F: 339 (pulse)
- DEF: 348 (pulse)
No. 1 air conditioning radiator damper servo sub-assembly (front mode) circuit malfunction Body Electrical > Air Conditioner > Active Test
Active Test Display Front Air Outlet Damper Control Servo Motor Data List Display Front Air Outlet Damper Control Servo Motor Actual Pulse OK
The value of the Data List changes in accordance with the operation of the Active Test.
Result
Proceed to OK NG
Result:
OK
See step 5
Result:
NG
See step 8
- Perform the Active Test according to the display on the GTS.
- CHECK AIR CONDITIONING RADIATOR ASSEMBLY (DAMPER)
Pre-procedure1
- Remove the No. 2 air conditioning radiator damper servo sub-assembly.
HINT:
Refer to DISASSEMBLY [10/2022 - ]
Post-procedure1
- None
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [10/2022 - ]
Result:
NG
REPAIR OR REPLACE AIR CONDITIONING RADIATOR ASSEMBLY
- Remove the No. 2 air conditioning radiator damper servo sub-assembly.