DTC P0EE3-14: A/C High Pressure Magnetic Valve Circuit Short to Ground or Open [08/2023 - ]: Description
The high pressure magnetic valve (No. 3 magnet valve assembly) is installed to the air conditioner tube and accessory assembly and is open when the ignition switch is turned off. When the ignition switch is turned to ON, the high pressure magnetic valve (No. 3 magnet valve assembly) opens and closes according to heat pump air conditioning control. When heat pump air conditioning control is performing cooling/serial dehumidification heating/cooling battery cooling/single battery cooling/heating/defrosting, the high pressure magnetic valve (No. 3 magnet valve assembly) is closed according to signals from the heat pump ECU assembly. When heat pump air conditioning control is performing parallel dehumidification heating, the high pressure magnetic valve (No. 3 magnet valve assembly) is open.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | DTC Output from | Priority | Note |
|---|---|---|---|---|---|---|---|---|
| P0EE3-14 | A/C High Pressure Magnetic Valve Circuit Short to Ground or Open | Diagnosis condition:
Malfunction status:
Detection time:
|
|
Does not come on | Memorized | Air Conditioner | A | - |
| Vehicle Condition | |||
|---|---|---|---|
| Pattern 1 | Pattern 2 | ||
| Diagnosis Condition | Ignition switch ON | ◦ | ◦ |
| Malfunction | Open in high pressure magnetic valve (No. 3 magnet valve assembly) circuit | ◦ | - |
| Short in high pressure magnetic valve (No. 3 magnet valve assembly) circuit | - | ◦ | |
| Detection Time | Continuously for 4 seconds or more | Continuously for 4 seconds or more | |
| Trip Count | 1 trip | 1 trip | |
HINT:
If the conditions of either of these patterns are detected, a DTC will be stored