Home >> Lexus >> 2024 >> RX 500h >> Repair and Diagnosis >> External Pages >> Different car >> Section 82 (Heating / Air Conditioning System - Diagnostic Codes (2 Of 3)) >> AIR CONDITIONING SYSTEM (for PHEV Model) >> DTC P0EBC-15: External Condenser Refrigerant Temperature Sensor Circuit Short to Battery or Open [08/2023 - ] >> Procedure

DTC P0EBC-15: External Condenser Refrigerant Temperature Sensor Circuit Short to Battery or Open [08/2023 - ]: Procedure

WARNING: This page is about a different car, the 2025 Lexus RX 450h+ and 2024 Lexus RX 450h+. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK EXTERNAL CONDENSER REFRIGERANT TEMPERATURE SENSOR (THERMOSTAT ASSEMBLY) CIRCUIT 

    Pre-procedure1

    • Disconnect the A60 external condenser refrigerant temperature sensor (thermostat assembly) connector.
    • Measure the voltage according to the value(s) in the table below.
      GTY1206732Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Front view of wire harness connector
      (to External Condenser Refrigerant Temperature Sensor (Thermostat Assembly))

      Standard Voltage

      Tester Connection Condition Specified Condition Result
      A60-2 (THO) - Body ground Ignition switch ON 0 to 5.5 V V

      Result

      Proceed to
      OK
      NG

    Post-procedure1

    • None

    Result: 

    NG 

    See step  5

    Result: 

    OK 

    See step  2

  2. CLEAR DTC 
    1. Clear the DTCs.

      Body Electrical > Air Conditioner > Clear DTCs 

      Result

      Proceed to
      NEXT

    Result: 

    NEXT 

    See step  3

  3. CHECK FOR DTC 

    Pre-procedure1

    • Turn the ignition switch off.
    • Disconnect the A60 external condenser refrigerant temperature sensor (thermostat assembly) connector.
      GTY1206731Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Front view of wire harness connector
      (to External Condenser Refrigerant Temperature Sensor (Thermostat Assembly))
    • Connect terminals 1 and 2 of the thermostat assembly connector on the wire harness side.
      GTY1070963Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *1 External Condenser Refrigerant Temperature Sensor (Thermostat Assembly)
      *2 Heat Pump ECU Assembly
    • Turn the ignition switch to ON and wait for 4 seconds or more.
    • Check for DTCs.

      Body Electrical > Air Conditioner > Trouble Codes 

      Result

      Result Proceed to
      P0EBC-11 is output A
      P0EBC-15 is output B

    Post-procedure1

    • None

    Result: 

    REPLACE EXTERNAL CONDENSER REFRIGERANT TEMPERATURE SENSOR (THERMOSTAT ASSEMBLY). Refer to  REMOVAL [08/2023 - ] 

    Result: 

    See step  4

  4. CHECK HARNESS AND CONNECTOR (EXTERNAL CONDENSER REFRIGERANT TEMPERATURE SENSOR - HEAT PUMP ECU ASSEMBLY) 

    Pre-procedure1

    • Disconnect the A60 external condenser refrigerant temperature sensor (thermostat assembly) connector.
    • Disconnect the A62 heat pump ECU assembly connector.
    • Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition Result
      A60-2 (THO) - A62-18 (TSUC) Always Below 1 Ω Ω
      A60-1 (SG) - A62-26 (SG-5) Always Below 1 Ω Ω

      Result

      Proceed to
      OK
      NG

    Post-procedure1

    • None

    Result: 

    OK 

    REPLACE HEAT PUMP ECU ASSEMBLY. Refer to  REMOVAL [08/2023 - ] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR 

  5. CHECK HARNESS AND CONNECTOR (EXTERNAL CONDENSER REFRIGERANT TEMPERATURE SENSOR - HEAT PUMP ECU ASSEMBLY) 

    Pre-procedure1

    • Disconnect the A60 external condenser refrigerant temperature sensor (thermostat assembly) connector.
    • Disconnect the A62 heat pump ECU assembly connector.
    • Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition Result
      A60-2 (THO) or A62-18 (TSUC) - Other terminals and body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Post-procedure1

    • None

    Result: 

    OK 

    REPLACE HEAT PUMP ECU ASSEMBLY. Refer to  REMOVAL [08/2023 - ] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR