Home >> Lexus >> 2024 >> RX 500h >> Repair and Diagnosis >> External Pages >> Different car >> Section 82 (Heating / Air Conditioning System - Diagnostic Codes (2 Of 3)) >> AIR CONDITIONING SYSTEM (for PHEV Model) >> DTC B3A0A-71: A/C Heating Electric Expansion Valve Actuator Stuck [08/2023 - ] >> Typical Malfunction Thresholds

Typical Malfunction Thresholds

WARNING: This page is about a different car, the 2025 Lexus RX 450h+ and 2024 Lexus RX 450h+. However, it is still accessible from the selected car via links, so may be relevant.

A malfunction is detected if any of the following conditions apply.

CONDITION 1

Refrigerant cycle Cooling Battery cooling or Battery Alone
Battery cooling after test mode OFF
High pressure failsafe mode ON
After high pressure protection recorded Recorded 10 times or more
The No. 1 cooler thermistor (duct inlet 1) temperature when the compressor is operating dropped 3°C or more compared with when the compressor is stopped
or
The No. 1 cooler thermistor (duct inlet 2) temperature when the compressor is operating dropped 3°C or more compared with when the compressor is stopped
Cannot detect 3 times or more
CONDITION 2

Refrigerant cycle A/C Cooling and Battery Cooling
Battery cooling after test mode ON
High pressure failsafe mode OFF
Cooler condenser assembly temperature 20 °C or higher
Opening angle of cooler expansion valve 38.5 % or higher
Sum of opening angle of No. 1 magnet valve assembly and No. 3 magnet valve assembly 10 % or higher
Average temperature of No. 2 air conditioning thermistor assembly (duct outlet 1) and No. 2 air conditioning thermistor assembly (duct outlet 2) 20 °C or higher
Refrigerant Cycle Battery Cooling
Battery Cooling after Test Mode ON
High Pressure Failsafe Mode OFF
Cooler condenser assembly temperature 20 °C or higher
Opening angle of No. 1 magnet valve assembly and No. 3 magnet valve assembly 38.5 % or higher
Average temperature of No. 2 air conditioning thermistor assembly (duct outlet 1) and No. 2 air conditioning thermistor assembly (duct outlet 2) 20 °C or higher