LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2024 >> RX 500h >> Repair and Diagnosis >> External Pages >> Different car >> Section 66 (Hybrid Control System - Diagnostic Codes (7 Of 7) & Circuit Tests (1 Of 2)) >> HYBRID CONTROL SYSTEM (for PHEV Model) >> DTC P320F-00: AC Charging Overpower [08/2023 - ] >> Procedure

DTC P320F-00: AC Charging Overpower [08/2023 - ]: Procedure

WARNING: This page is about a different car, the 2025 Lexus RX 450h+ and 2024 Lexus RX 450h+. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK DTC OUTPUT (HYBRID CONTROL, HV BATTERY AND PLUG-IN CONTROL) 

    Pre-procedure1

    1. None.

      Procedure1

    2. Check for DTCs.

      Powertrain > Hybrid Control > Trouble Codes 

      Powertrain > HV Battery > Trouble Codes 

      Powertrain > Plug-in Control > Trouble Codes 

      Result

      Result Proceed to
      P320F-00 only is output, or DTCs except the ones in the table below are also output. A
      DTCs of hybrid control system in the tables below are output. B
      DTCs of hybrid battery system in the tables below are output. C
      DTCs of plug-in charge control system in the tables below are output. D
      Malfunction Content System Relevant DTC
      Microcomputer malfunction Hybrid control system P0606-47 Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure
      P0606-87 Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message
      P060A-47 Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure
      P060A-87 Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message
      P060B-49 Hybrid/EV Powertrain Control Module A/D Processing Internal Electronic Failure
      P0A1F-94 Hybrid/EV Battery Energy Control Module Unexpected Operation
      P1C9E-9F Hybrid/EV System Reset Stuck Off
      Hybrid battery system P060A-47 Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure
      P060B-16 Hybrid/EV Battery Energy Control Module A/D Processing Circuit Voltage Below Threshold
      P060B-49 Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure
      Communication system malfunction Hybrid control system U0111-87 Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message
      Hybrid battery system P0606-87 Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message
      P060A-87 Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message
      Plug-in charge control system U1150-87 Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message
      Sensor and actuator circuit malfunction Hybrid control system P0ABF-00 Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance
      P0B23-1C Hybrid/EV Battery "A" Voltage Sensor Voltage Out of Range
      Hybrid battery system P0ABF-11 Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground
      P0ABF-15 Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open
      P0ABF-28 Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure
      P0ABF-2A Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range
      P0B0E-11 Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground
      P0B0E-15 Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open
      P0B13-62 Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure
      P0E2D-00 Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance
      P1A00-1C Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range
      P1A05-1C Hybrid Battery Stack 3 Cell Voltage Detection Voltage Out of Range
      P1A0A-1C Hybrid Battery Stack 4 Cell Voltage Detection Voltage Out of Range
      P1AFD-1C Flying Capacitor/Internal Control Module Hybrid/EV Battery Monitor Voltage Out of Range
      P1C9F-11 Hybrid/EV Battery Current Sensor for Driving Control Circuit Short to Ground
      P1C9F-15 Hybrid/EV Battery Current Sensor for Driving Control Circuit Short to Auxiliary Battery or Open
      P1C9F-1C Hybrid/EV Battery Current Sensor for Driving Control Voltage Out of Range
      P1CBB-12 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery
      P1CBB-14 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open
      P2BE4-11 Hybrid/EV Battery Pack Current Sensor "C" Low Circuit Short to Ground
      P2BE4-15 Hybrid/EV Battery Pack Current Sensor "C" High Circuit Short to Auxiliary Battery or Open
      P2BE4-1C Hybrid/EV Battery Pack Current Sensor "C" Circuit Range/Performance Circuit Voltage Out of Range
      P2BE4-28 Hybrid/EV Battery Pack Current Sensor "C" Circuit Range/Performance Signal Bias Level Out of Range / Zero Adjustment Failure
      P301A-1C Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range
      System malfunction Plug-in charge control system P1C1E-00 Charging Power High

      HINT: 

      • P320F-00 may be output as a result of the malfunction indicated by the DTCs above.
        1. The chart above is listed in inspection order of priority.
        2. Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)

      Post-procedure1

    3. Turn the ignition switch off.

    Result: 

    REPLACE ELECTRIC VEHICLE CHARGER ASSEMBLY. Refer to  REMOVAL [08/2023 - ] 

    Result: 

    GO TO DTC CHART (HYBRID CONTROL SYSTEM). Refer to  DIAGNOSTIC TROUBLE CODE CHART [08/2023 - 10/2024]  , or refer to  DIAGNOSTIC TROUBLE CODE CHART [10/2024 - ] 

    Result: 

    GO TO DTC CHART (HYBRID BATTERY SYSTEM). Refer to  DIAGNOSTIC TROUBLE CODE CHART [08/2023 - ] 

    Result: 

    GO TO DTC CHART (PLUG-IN CHARGE CONTROL SYSTEM). Refer to  DIAGNOSTIC TROUBLE CODE CHART [08/2023 - ]