DTC P0A93-00: Inverter "A" Cooling System Performance [08/2023 - ]: Procedure
- CHECK DTC OUTPUT
Pre-procedure1
- None.
Procedure1
- Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes
Powertrain > Engine > Trouble Codes
Powertrain > Motor Generator > Trouble Codes
Result
Result Proceed to P0A93-00 only is output, or DTCs except the ones in the table below are also output. A DTCs of hybrid control system in the table below are output. B DTCs of motor generator control system in the table below are output. C TABLE 1Malfunction Content System Relevant DTC Insulation malfunction Hybrid control system P1C7C-49 Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure P1C7D-49 Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure P1C7E-49 Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure P1C7F-49 Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure P1C80-49 Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure TABLE 2Malfunction Content System Relevant DTC Sensor and actuator circuit malfunction Hybrid control system P0C73-96 Motor Electronics Coolant Pump "A" Component Internal Failure P314A-31 Motor Electronics Coolant Pump "A" No Signal Motor generator control system P0A00-11 Motor Electronics Coolant Temperature Sensor Circuit Short to Ground P0A00-15 Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open HINT:
- P0A93-00 may be output as a result of the malfunction indicated by the DTCs above.
- The chart above is listed in inspection order of priority.
- Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
- P0A93-00 may be output as a result of the malfunction indicated by the DTCs above.
- Turn the ignition switch off.
Result:
B
GO TO DTC CHART (HYBRID CONTROL SYSTEM). Refer to DIAGNOSTIC TROUBLE CODE CHART [08/2023 - 10/2024] , or refer to DIAGNOSTIC TROUBLE CODE CHART [10/2024 - ]
Result:
C
GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM). Refer to DIAGNOSTIC TROUBLE CODE CHART [08/2023 - ]
Result:
A
See step 2
- None.
- CHECK CONNECTOR CONNECTION CONDITION (HYBRID MOTOR CONTROL INVERTER ASSEMBLY CONNECTOR)
Refer to PROCEDURE - Step 3
Result
Result Proceed to OK A NG (The connector is not connected securely.) B NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C Result:
B
CONNECT SECURELY
Result:
C
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
A
See step 3
- CHECK COOLING SYSTEM
Refer to Cooling System [08/2023 - ]
HINT:
If the "Cooling System" inspection results are normal, perform the next step.
Result
Proceed to NEXT Result:
NEXT
REPLACE HV COOLANT. Refer to REPLACEMENT [10/2022 - ]