DTC P065C-07: Generator "A" Mechanical Performance Mechanical Failure [10/2022 - ]: Procedure
- CHECK FAN AND GENERATOR V BELT
Refer to ON-VEHICLE INSPECTION [10/2022 - ]
Result
Result OK NG Result:
NG
REPAIR OR REPLACE FAN AND GENERATOR V BELT. Refer to REMOVAL [10/2022 - ]
Result:
OK
See step 2
- CHECK V-RIBBED BELT TENSIONER ASSEMBLY
Refer to PROCEDURE - Step 7
Result
Result OK NG Result:
NG
REPAIR OR REPLACE V-RIBBED BELT TENSIONER ASSEMBLY. Refer to PROCEDURE - Step 77
Result:
OK
See step 3
- CHECK GENERATOR ASSEMBLY WIRING
See step 5
Result
Result OK NG Result:
NG
REPAIR OR REPLACE GENERATOR ASSEMBLY WIRING
Result:
OK
See step 4
- CHECK FOR ABNORMAL NOISE
See step 6
Result
Result OK NG Result:
NG
REPAIR OR REPLACE GENERATOR ASSEMBLY. Refer to REMOVAL [10/2022 - ]
Result:
OK
See step 5
- CHARGING CIRCUIT WITHOUT LOAD
See step 7
Result
Result OK NG Result:
NG
REPAIR OR REPLACE GENERATOR ASSEMBLY. Refer to REMOVAL [10/2022 - ]
Result:
OK
See step 6
- CHARGING CIRCUIT WITH LOAD
See step 8
Result
Result OK NG Result:
OK
CHECK FOR INTERMITTENT PROBLEMS. Refer to CHECK FOR INTERMITTENT PROBLEMS [10/2022 - ]
Result:
NG
REPAIR OR REPLACE GENERATOR ASSEMBLY. Refer to REMOVAL [10/2022 - ]