Inner Rear View Mirror Assembly Communication Stop Mode [10/2022 - ]: Procedure
WARNING: This page is about a different car, the 2025 Lexus RX 350, 2024 Lexus RX 350, and 2023 Lexus RX 350. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK FOR OPEN IN CAN BUS LINES (INNER REAR VIEW MIRROR ASSEMBLY BRANCH LINE)
- Disconnect the cable from the negative (-) battery terminal.
- Disconnect the K6 inner rear view mirror assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition K6-9 (CANH) - K6-10 (CANL) Cable disconnected from negative (-) battery terminal 54 to 69 Ω Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE CAN BRANCH LINES OR CONNECTOR (INNER REAR VIEW MIRROR ASSEMBLY)
Result:
OK
See step 2
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition K6-2 (E) - Body ground Cable disconnected from negative (-) battery terminal Below 1 Ω - Reconnect the cable to the negative (-) battery terminal.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition K6-1 (IG) - Body ground Ignition switch ON 11 to 14 V Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 3
- Measure the resistance according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition K6-6 (+B) - Body ground Ignition switch ON 10.5 to 16 V Result
Proceed to OK NG
Result:
OK
REPLACE INNER REAR VIEW MIRROR ASSEMBLY. Refer to REMOVAL [10/2022 - ]
Result:
NG
GO TO STOP AND START SYSTEM (FOR BACKUP BOOST CONVERTER CIRCUIT). Refer to Backup Boost Converter Circuit [10/2022 - ]