DTC P1770-62: Door Lock Switch / Curtesy Switch Signal Compare Failure [10/2022 - ]: Procedure
- READ VALUE USING GTS (DOOR OPEN SWITCH STATUS)
Pre-procedure1
- Turn the ignition switch to ON.
- Read the Data List according to the display on the GTS.
Powertrain > Transmission > Data List
Tester Display Door Open Switch Status Result
Result Proceed to Does not change ON/OFF in accordance with the opening/closing of the driver door A Changes ON/OFF in accordance with the opening/closing of the driver door B
Post-procedure1
- Turn the ignition switch off.
Result:
B
GO TO CAN COMMUNICATION SYSTEM. Refer to DIAGNOSIS SYSTEM [10/2022 - 08/2023] , or refer to DIAGNOSIS SYSTEM [08/2023 - 10/2024] , or refer to DIAGNOSIS SYSTEM [10/2024 - ]
Result:
A
See step 2
- INSPECT TRANSMISSION FLOOR SHIFT ASSEMBLY (SHIFT CONTROL ECU) (DROP TERMINAL VOLTAGE)
Pre-procedure1
- Open the driver door.
- Turn the ignition switch to ON.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition Result C35-8 (DROP) - Body ground Ignition switch ON and driver door open Below 1 V V Result
Proceed to OK NG *a Component with harness connected
Transmission Floor Shift Assembly (Shift Control ECU)
Post-procedure1
- Turn the ignition switch off.
- Close the driver door.
Result:
OK
REPLACE TRANSMISSION FLOOR SHIFT ASSEMBLY (SHIFT CONTROL ECU). Refer to REMOVAL [10/2022 - ]
Result:
NG
See step 3
- INSPECT INTEGRATION CONTROL SUPPLY (INTEGRATED CAPACITOR) (DRO2 TERMINAL VOLTAGE)
Pre-procedure1
- Open the driver door.
- Turn the ignition switch to ON.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition Result H116-4 (DRO2) - Body ground Ignition switch ON and driver door open Below 1 V V Result
Proceed to OK NG *a Component with harness connected
(Integration Control Supply (Integrated Capacitor))
Post-procedure1
- Turn the ignition switch off.
- Close the driver door.
Result:
OK
REPAIR OR REPLACE HARNESS OR CONNECTOR (INTEGRATION CONTROL SUPPLY (INTEGRATED CAPACITOR) - TRANSMISSION FLOOR SHIFT ASSEMBLY (SHIFT CONTROL ECU))
Result:
NG
See step 4
- INSPECT INTEGRATION CONTROL SUPPLY (INTEGRATED CAPACITOR) (DRO1 TERMINAL VOLTAGE)
Pre-procedure1
- Open the driver door.
- Turn the ignition switch to ON.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition Result H116-17 (DRO1) - Body ground Ignition switch ON and driver door open Below 1 V V Result
Proceed to OK NG *a Component with harness connected
(Integration Control Supply (Integrated Capacitor))
Post-procedure1
- Turn the ignition switch off.
- Close the driver door.
Result:
OK
REPLACE INTEGRATION CONTROL SUPPLY (INTEGRATED CAPACITOR). Refer to REMOVAL [10/2022 - 08/2023] , or refer to REMOVAL [08/2023 - ]
Result:
NG
See step 5
- INSPECT FRONT DOOR LOCK WITH MOTOR ASSEMBLY LH (DCTY TERMINAL VOLTAGE)
Pre-procedure1
- Open the driver door.
- Turn the ignition switch to ON.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition Result D34-7 (DCTY) - Body ground Ignition switch ON and driver door open Below 1 V V Result
Proceed to OK NG *a Component with harness connected
(Front Door Lock with Motor Assembly LH)
Post-procedure1
- Turn the ignition switch off.
- Close the driver door.
Result:
OK
REPAIR OR REPLACE HARNESS OR CONNECTOR (INTEGRATION CONTROL SUPPLY (INTEGRATED CAPACITOR) - FRONT DOOR LOCK WITH MOTOR ASSEMBLY LH)
Result:
NG
REPLACE FRONT DOOR LOCK WITH MOTOR ASSEMBLY LH. Refer to REMOVAL [10/2022 - 08/2023] , or refer to REMOVAL [08/2023 - ]