LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2024 >> RX 500h >> Repair and Diagnosis >> External Pages >> Different car >> Section 109 (Heating / Air Conditioning System - Diagnostic Codes (1 Of 2)) >> AIR CONDITIONING SYSTEM (for Gasoline Model) >> DTC B143A-87: Lost Communication with Air Inlet Damper Control Servo Motor LIN Missing Message [10/2022 - ] >> Procedure

DTC B143A-87: Lost Communication with Air Inlet Damper Control Servo Motor LIN Missing Message [10/2022 - ]: Procedure

WARNING: This page is about a different car, the 2025 Lexus RX 350, 2024 Lexus RX 350, and 2023 Lexus RX 350. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK FOR DTC 
    1. Check for DTCs.

      Body Electrical > Air Conditioner > Trouble Codes 

      Result

      Result Proceed to
      B142A-88 is output A
      B142A-88 is not output B

    Result: 

    A 

    GO TO DTC B142A-88. Refer to  DTC B142A-88: Servo Motor LIN Communication Bus off [10/2022 - ]  

    Result: 

    B 

    See step  2

  2. INSPECT AIR CONDITIONING HARNESS ASSEMBLY 

    Pre-procedure1

    • Disconnect the A No. 1 air conditioning radiator damper servo sub-assembly connector.
    • Disconnect the B No. 5 air conditioning radiator damper servo sub-assembly connector.
    • Measure the resistance according to the value(s) in the table below.
      GTY1072103Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Front view of wire harness connector
      (to No. 1 Air Conditioning Radiator Damper Servo Sub-assembly)
      *b Front view of wire harness connector
      (to No. 5 Air Conditioning Radiator Damper Servo Sub-assembly)

      Standard Resistance

      Tester Connection Condition Specified Condition Result
      A-1 (M-) - B-5 (M-) Always Below 1 Ω Ω
      A-2 (M+) - B-4 (M+) Always Below 1 Ω Ω
      A-3 (STE2) - B-3 (STE2) Always Below 1 Ω Ω
      A-4 (STE1) - B-2 (STE1) Always Below 1 Ω Ω
      A-5 (GND) - B-1 (GND) Always Below 1 Ω Ω
      A-1 (M-) or B-5 (M-) - Other terminals and body ground Always 10 kΩ or higher kΩ
      A-2 (M+) or B-4 (M+) - Other terminals and body ground Always 10 kΩ or higher kΩ
      A-3 (STE2) or B-3 (STE2) - Other terminals and body ground Always 10 kΩ or higher kΩ
      A-4 (STE1) or B-2 (STE1) - Other terminals and body ground Always 10 kΩ or higher kΩ

      Result

      Proceed to
      OK
      NG

    Post-procedure1

    • None

    Result: 

    OK 

    REPLACE NO. 5 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY. Refer to  DISASSEMBLY [10/2022 - ] 

    Result: 

    NG 