Caution / Notice / Hint
WARNING: This page is about a different car, the 2025 Lexus RX 450h+ and 2024 Lexus RX 450h+. However, it is still accessible from the selected car via links, so may be relevant.
WARNING:
Refer to the precautions before inspecting high voltage circuit.
Refer to PRECAUTION [08/2023 - ]
NOTE:
- To prevent the key from being locked in the vehicle, make sure to enter e-latch inspection mode and enable the manual release handle before disconnecting the cable from the negative (-) auxiliary battery terminal.
- After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
- When disconnecting and reconnecting the auxiliary battery.
Refer to WORK PROCEDURE [10/2022 - ]
HINT:
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
HINT:
P0E2D-00 may be output as a result of the malfunction indicated by the DTCs in table below.
- The chart above is listed in inspection order of priority.
- Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Microcomputer malfunction | P0A1F-94 | Hybrid/EV Battery Energy Control Module Unexpected Operation |
| P062F-46 | Hybrid/EV Battery Energy Control Module EEPROM Calibration / Parameter Memory Failure | |
| P0A1D-94 | Hybrid/EV Powertrain Control Module Unexpected Operation | |
| P060A-47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure | |
| P060B-49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure | |
| P0606-87 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message | |
| P060A-87 | Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message | |
| P0606-29 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Signal Invalid | |
| U0293-87 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message | |
| U0100-87 | Lost Communication with ECM/PCM "A" Missing Message | |
| U1150-87 | Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message | |
| P0560-14 | System Voltage (BATT) Circuit Short to Ground or Open | |
| P0ABF-00 | Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance | |