Inspection [09/2014 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- INSPECT TRANSMISSION REVOLUTION SENSOR (NT)
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Transmission Revolution Sensor (NT))Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 560 to 680 Ω If the result is not as specified, replace the transmission revolution sensor (NT).
- Measure the resistance according to the value(s) in the table below.
- INSPECT TRANSMISSION REVOLUTION SENSOR (SP2)
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Transmission Revolution Sensor (SP2))Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 560 to 680 Ω If the result is not as specified, replace the transmission revolution sensor (SP2).
- Measure the resistance according to the value(s) in the table below.