VC Output Circuit [09/2014 - 11/2017]: Description
WARNING: This page is about a different car, the 2017 Lexus RC 350, 2017 Lexus RC 300, 2016 Lexus RC 350, 2016 Lexus RC 300, and 2015 Lexus RC 350. However, it is still accessible from the selected car via links, so may be relevant.
The ECM constantly generates 5 V power source voltage from the battery voltages supplied to the +B, +B2 (BATT) terminal to operate the microprocessor. The ECM also provides this power to the sensors through the VC output circuit.
When the VC circuit has a short circuit, the microprocessor in the ECM and sensors that are supplied power through the VC circuit are deactivated because power is not supplied from the VC circuit. When the system is in this condition, it will not start.