LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2024 >> NX 250 FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 22 (Heating / Air Conditioning System - Diagnostic Codes, Circuit Tests & Symptom Tests) >> AIR CONDITIONING SYSTEM (for HEV Model) >> Weak Blower Output [11/2021 - ] >> Procedure

Weak Blower Output [11/2021 - ]: Procedure

WARNING: This page is about a different car, the 2025 Lexus NX 350h, 2024 Lexus NX 350h, 2023 Lexus NX 350h, and 2022 Lexus NX 350h. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK AIR CONDITIONING SYSTEM 
    1. Operate the blower switch with the following conditions met and check that the airflow volume changes.
      Blower Speed Condition
      LO → HI
      • Temperature setting: MAX COLD
      • Air outlet mode: FACE
      • A/C switch: Off

      OK

      Airflow volume increases.

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    GO TO OTHER DIAGNOSIS PROCEDURE (Blower Motor Circuit). Refer to  Blower Motor Circuit [11/2021 - ]  

    Result: 

    OK 

    See step  2

  2. CHECK ECO MODE SETTING 
    1. Confirm that ECO HEAT/COOL switch (radio and display receiver assembly) is set to off.
    2. Confirm that ECO drive mode is set to off.

      HINT: 

      When the ECO drive mode is set to ON, the air conditioning amplifier assembly performs minimal air conditioning control in order to promote the improvement of fuel economy. Ensure that the customer understands that the airflow volume will be decreased compared to normal operation.

      Control Control Summary
      Air Volume Control Sets the blower level to less.

      Result

      Proceed to
      NEXT

    Result: 

    NEXT 

    See step  3

  3. CHECK CLEAN AIR FILTER 
    1. Visually check the clean air filter.

      OK

      The clean air filter is not dirty or clogging.

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPLACE CLEAN AIR FILTER. Refer to  REMOVAL [11/2021 - ] 

    Result: 

    OK 

    See step  4

  4. CHECK EVAPORATOR TEMP. SENSOR (NO. 1 COOLER THERMISTOR) 
    1. Check the installation condition of the evaporator temp. sensor (No. 1 cooler thermistor).

      OK

      Evaporator temp. sensor (No. 1 cooler thermistor) is installed correctly.

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REINSTALL EVAPORATOR TEMP. SENSOR (NO. 1 COOLER THERMISTOR). Refer to  INSTALLATION [11/2021 - 03/2024]  , or refer to  INSTALLATION [03/2024 - ] 

    Result: 

    OK 

    See step  5

  5. CHECK ASPIRATOR PIPE 
    1. Check the installation condition of the aspirator pipe.

      OK

      The aspirator pipe is installed correctly.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY OR NO. 1 COOLER EVAPORATOR SUB-ASSEMBLY. Refer to  REMOVAL [11/2021 - 03/2022]  , or refer to  REMOVAL [03/2022 - 03/2024]  , or refer to  REMOVAL [03/2024 - ] 

    Result: 

    NG 

    INSTALL ASPIRATOR PIPE. Refer to  REASSEMBLY [11/2021 - 03/2024]  , or refer to  REASSEMBLY [03/2024 - ]