Operating Light Control Rheostat does not Change Light Brightness [11/2021 - ]: Procedure
- PERFORM ACTIVE TEST USING GTS
- Perform the Active Test according to the display on the GTS.
Body Electrical > Combination Meter > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Light Control Switch (UP) Performs the same operation as pressing the light control rheostat up switch OFF/ON - Light Control Switch (DOWN) Performs the same operation as pressing the light control rheostat down switch OFF/ON - Body Electrical > Combination Meter > Active Test
Tester Display Light Control Switch (UP) Body Electrical > Combination Meter > Active Test
Tester Display Light Control Switch (DOWN) Result
Result Proceed to Active Test can be performed correctly A Active Test cannot be performed correctly B
Result:
B
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [11/2021 - ]
Result:
A
See step 2
- Perform the Active Test according to the display on the GTS.
- READ VALUE USING GTS
- Read the Data List according to the display on the GTS.
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Light Control Switch (UP) Light control rheostat up switch operation OFF or ON OFF: Switch released
ON: Switch pushed- Light Control Switch (DOWN) Light control rheostat down switch operation OFF or ON OFF: Switch released
ON: Switch pushed- Body Electrical > Combination Meter > Data List
Tester Display Light Control Switch (UP) Light Control Switch (DOWN) Result
Result Proceed to The value of the Data List item is correct, and the combination meter assembly operates correctly A The value of the Data List item is correct, but the combination meter assembly does not operate correctly B The Data List item changes correctly C
Result:
A
USE SIMULATION METHOD TO CHECK. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [11/2021 - ]
Result:
B
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [11/2021 - ]
Result:
C
See step 3
- Read the Data List according to the display on the GTS.
- INSPECT TRIP SWITCH
Refer to INSPECTION [11/2021 - ]
Result
Proceed to OK NG Result:
NG
REPLACE TRIP SWITCH. Refer to REMOVAL [11/2021 - ]
Result:
OK
See step 4
- CHECK HARNESS AND CONNECTOR (TRIP SWITCH - COMBINATION METER ASSEMBLY)
- Disconnect the D22 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition D81-5 (RV) - D22-28 (TR) Always Below 1 Ω D81-7 (E) - D22-26 (SW3) Always Below 1 Ω D81-5 (RV) or D22-28 (TR) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [11/2021 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR