Entire Combination Meter does not Operate [12/2023 - ]: Procedure
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND)
- Disconnect the E4 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition E4-1 (EP) - Body ground Always Below 1 Ω E4-2 (ES) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition E4-6 (IG+) - Body ground Ignition switch off Below 1 V Ignition switch ON 11 to 14 V E4-5 (B) - Body ground Always 11 to 14 V Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [12/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR