Home >> Lexus >> 2023 >> NX 250 AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 9 (Electronically Controlled Brake System - Diagnostic Codes (3 Of 6)) >> ELECTRONICALLY CONTROLLED BRAKE SYSTEM (for HEV Model) >> DTC C0597-49: Brake System Control Module "A" Internal Electronic Failure; DTC C12F6-62: Left Front Wheel ABS Hold Solenoid / Right Front Wheel ABS Hold Solenoid Signal Compare Failure; DTC C12F7-62: Left Rear Wheel ABS Hold Solenoid / Right Rear Wheel ABS Hold Solenoid Signal Compare Failure; DTC C13BF-62: Brake Pressure Control Solenoid "A" / "B" Signal Compare Failure [11/2021 - ] >> Typical Enabling Conditions

Typical Enabling Conditions

WARNING: This page is about a different car, the 2025 Lexus NX 350h, 2024 Lexus NX 350h, 2023 Lexus NX 350h, and 2022 Lexus NX 350h. However, it is still accessible from the selected car via links, so may be relevant.
C0597 (CASE 1)

Monitor runs whenever the following DTCs are not stored C12A7: ABS hold solenoid (FL) circuit low
C12A8: ABS hold solenoid (FL) circuit high
C12B2: ABS release solenoid (FL) circuit low
C12B3: ABS release solenoid (FL) circuit high
C12BD: ABS hold solenoid (FR) circuit low
C12BE: ABS hold solenoid (FR) circuit high
C12C8: ABS release solenoid (FR) circuit low
C12C9: ABS release solenoid (FR) circuit high
C12D3: ABS hold solenoid (RL) circuit low
C12D4: ABS hold solenoid (RL) circuit high
C12DE: ABS release solenoid (RL) circuit low
C12DF: ABS release solenoid (RL) circuit high
C12E9: ABS hold solenoid (RR) circuit low
C12EA: ABS hold solenoid (RR) circuit high
C12F4: ABS release solenoid (RR) circuit low
C12F5: ABS release solenoid (RR) circuit high
C12F6: ABS hold solenoid other functional
C12F7: ABS hold solenoid other functional
C137C: Brake system voltage input out of range low
C137D: Brake system voltage input out of range high
C13BF: SM solenoid other functional
C13C2: SM1 solenoid circuit low
C13C3: SM1 solenoid circuit high
C13CB: SM2 solenoid circuit low
C13CC: SM2 solenoid circuit high
C143B: Brake system voltage solenoid relay stuck
C143C: Brake system voltage open circuit
All of the following conditions are met -
Command to solenoid relay On
Power supply for solenoid Higher than 6 V
+BS voltage 9.5 V or more and 17.4 V or less
C0597 (CASE 2)

Monitor runs whenever the following DTCs are not stored C12A7: ABS hold solenoid (FL) circuit low
C12A8: ABS hold solenoid (FL) circuit high
C12B2: ABS release solenoid (FL) circuit low
C12B3: ABS release solenoid (FL) circuit high
C12BD: ABS hold solenoid (FR) circuit low
C12BE: ABS hold solenoid (FR) circuit high
C12C8: ABS release solenoid (FR) circuit low
C12C9: ABS release solenoid (FR) circuit high
C12D3: ABS hold solenoid (RL) circuit low
C12D4: ABS hold solenoid (RL) circuit high
C12DE: ABS release solenoid (RL) circuit low
C12DF: ABS release solenoid (RL) circuit high
C12E9: ABS hold solenoid (RR) circuit low
C12EA: ABS hold solenoid (RR) circuit high
C12F4: ABS release solenoid (RR) circuit low
C12F5: ABS release solenoid (RR) circuit high
C12F6: ABS hold solenoid other functional
C12F7: ABS hold solenoid other functional
C137C: Brake system voltage input out of range low
C137D: Brake system voltage input out of range high
C13BF: SM solenoid other functional
C13C2: SM1 solenoid circuit low
C13C3: SM1 solenoid circuit high
C13CB: SM2 solenoid circuit low
C13CC: SM2 solenoid circuit high
C143B: Brake system voltage solenoid relay stuck
C143C: Brake system voltage open circuit
All of the following conditions are met -
+BS voltage 9.5 V or more
Solenoid relay Off
ASIC output permission Off
C0597 (CASE 3)

Monitor runs whenever the following DTCs are not stored C12A7: ABS hold solenoid (FL) circuit low
C12A8: ABS hold solenoid (FL) circuit high
C12B2: ABS release solenoid (FL) circuit low
C12B3: ABS release solenoid (FL) circuit high
C12BD: ABS hold solenoid (FR) circuit low
C12BE: ABS hold solenoid (FR) circuit high
C12C8: ABS release solenoid (FR) circuit low
C12C9: ABS release solenoid (FR) circuit high
C12D3: ABS hold solenoid (RL) circuit low
C12D4: ABS hold solenoid (RL) circuit high
C12DE: ABS release solenoid (RL) circuit low
C12DF: ABS release solenoid (RL) circuit high
C12E9: ABS hold solenoid (RR) circuit low
C12EA: ABS hold solenoid (RR) circuit high
C12F4: ABS release solenoid (RR) circuit low
C12F5: ABS release solenoid (RR) circuit high
C12F6: ABS hold solenoid other functional
C12F7: ABS hold solenoid other functional
C137C: Brake system voltage input out of range low
C137D: Brake system voltage input out of range high
C13BF: SM solenoid other functional
C13C2: SM1 solenoid circuit low
C13C3: SM1 solenoid circuit high
C13CB: SM2 solenoid circuit low
C13CC: SM2 solenoid circuit high
C143B: Brake system voltage solenoid relay stuck
C143C: Brake system voltage open circuit
All of the following conditions are met -
+BS voltage 9.5 V or more
Solenoid relay On
ASIC output permission Off
Solenoid current output order value 160 mA
Power supply voltage for solenoid 6 V or more
C0597 (CASE 4)

Monitor runs whenever the following DTCs are not stored C12A7: ABS hold solenoid (FL) circuit low
C12A8: ABS hold solenoid (FL) circuit high
C12B2: ABS release solenoid (FL) circuit low
C12B3: ABS release solenoid (FL) circuit high
C12BD: ABS hold solenoid (FR) circuit low
C12BE: ABS hold solenoid (FR) circuit high
C12C8: ABS release solenoid (FR) circuit low
C12C9: ABS release solenoid (FR) circuit high
C12D3: ABS hold solenoid (RL) circuit low
C12D4: ABS hold solenoid (RL) circuit high
C12DE: ABS release solenoid (RL) circuit low
C12DF: ABS release solenoid (RL) circuit high
C12E9: ABS hold solenoid (RR) circuit low
C12EA: ABS hold solenoid (RR) circuit high
C12F4: ABS release solenoid (RR) circuit low
C12F5: ABS release solenoid (RR) circuit high
C12F6: ABS hold solenoid other functional
C12F7: ABS hold solenoid other functional
C137C: Brake system voltage input out of range low
C137D: Brake system voltage input out of range high
C13BF: SM solenoid other functional
C13C2: SM1 solenoid circuit low
C13C3: SM1 solenoid circuit high
C13CB: SM2 solenoid circuit low
C13CC: SM2 solenoid circuit high
C143B: Brake system voltage solenoid relay stuck
C143C: Brake system voltage open circuit
All of the following conditions are met -
+BS voltage 9.5 V or more
Solenoid relay On
ASIC output permission Off
NO solenoid current output order value 160 mA
NC solenoid output order value On
Power supply voltage for solenoid 6 V or more
C0597 (CASE 5)

Monitor runs whenever the following DTCs are not stored C12A7: ABS hold solenoid (FL) circuit low
C12A8: ABS hold solenoid (FL) circuit high
C12B2: ABS release solenoid (FL) circuit low
C12B3: ABS release solenoid (FL) circuit high
C12BD: ABS hold solenoid (FR) circuit low
C12BE: ABS hold solenoid (FR) circuit high
C12C8: ABS release solenoid (FR) circuit low
C12C9: ABS release solenoid (FR) circuit high
C12D3: ABS hold solenoid (RL) circuit low
C12D4: ABS hold solenoid (RL) circuit high
C12DE: ABS release solenoid (RL) circuit low
C12DF: ABS release solenoid (RL) circuit high
C12E9: ABS hold solenoid (RR) circuit low
C12EA: ABS hold solenoid (RR) circuit high
C12F4: ABS release solenoid (RR) circuit low
C12F5: ABS release solenoid (RR) circuit high
C12F6: ABS hold solenoid other functional
C12F7: ABS hold solenoid other functional
C137C: Brake system voltage input out of range low
C137D: Brake system voltage input out of range high
C13BF: SM solenoid other functional
C13C2: SM1 solenoid circuit low
C13C3: SM1 solenoid circuit high
C13CB: SM2 solenoid circuit low
C13CC: SM2 solenoid circuit high
C143B: Brake system voltage solenoid relay stuck
C143C: Brake system voltage open circuit
All of the following conditions are met -
Solenoid relay Off
ASIC output permission Off
ASIC send data NG answer
C12F6

Monitor runs whenever the following DTCs are not stored C0597 (Case 1): ABS hold solenoid circuit stuck
C0597 (Case 2 to 5): ABS hold solenoid performance
C12A7: ABS hold solenoid (FL) circuit low
C12A8: ABS hold solenoid (FL) circuit high
C12B2: ABS release solenoid (FL) circuit low
C12B3: ABS release solenoid (FL) circuit high
C12BD: ABS hold solenoid (FR) circuit low
C12BE: ABS hold solenoid (FR) circuit high
C12C8: ABS release solenoid (FR) circuit low
C12C9: ABS release solenoid (FR) circuit high
C12D3: ABS hold solenoid (RL) circuit low
C12D4: ABS hold solenoid (RL) circuit high
C12DE: ABS release solenoid (RL) circuit low
C12DF: ABS release solenoid (RL) circuit high
C12E9: ABS hold solenoid (RR) circuit low
C12EA: ABS hold solenoid (RR) circuit high
C12F4: ABS release solenoid (RR) circuit low
C12F5: ABS release solenoid (RR) circuit high
C12F7: ABS hold solenoid other functional
C137C: Brake system voltage input out of range low
C137D: Brake system voltage input out of range high
C13BF: SM solenoid other functional
C13C2: SM1 solenoid circuit low
C13C3: SM1 solenoid circuit high
C13CB: SM2 solenoid circuit low
C13CC: SM2 solenoid circuit high
C143B: Brake system voltage solenoid relay stuck
C143C: Brake system voltage open circuit
All of the following conditions are met A, B, C, D, E, F, G and H
A. Command to solenoid relay On
B. Power supply for solenoid 9.5 V or more
C. +BS voltage 17.4 V or less
D. Following condition is met 0.120 seconds or more
Difference SFRH target current value (0.018 seconds before) and SFRH target current value Less than 0.022 A
E. Following condition is met 0.120 seconds or more
Difference SFLH target current value (0.018 seconds before) and SFLH target current value Less than 0.022 A
F. SFRH target current value SFLH target current value
G. SFRH target current value 0.25 A or more, and 1 A or less
H. SFLH target current value 0.25 A or more, and 1 A or less
C12F7

Monitor runs whenever the following DTCs are not stored C0597 (Case 1): ABS hold solenoid circuit stuck
C0597 (Case 2 to 5): ABS hold solenoid performance
C12A7: ABS hold solenoid (FL) circuit low
C12A8: ABS hold solenoid (FL) circuit high
C12B2: ABS release solenoid (FL) circuit low
C12B3: ABS release solenoid (FL) circuit high
C12BD: ABS hold solenoid (FR) circuit low
C12BE: ABS hold solenoid (FR) circuit high
C12C8: ABS release solenoid (FR) circuit low
C12C9: ABS release solenoid (FR) circuit high
C12D3: ABS hold solenoid (RL) circuit low
C12D4: ABS hold solenoid (RL) circuit high
C12DE: ABS release solenoid (RL) circuit low
C12DF: ABS release solenoid (RL) circuit high
C12E9: ABS hold solenoid (RR) circuit low
C12EA: ABS hold solenoid (RR) circuit high
C12F4: ABS release solenoid (RR) circuit low
C12F5: ABS release solenoid (RR) circuit high
C12F6: ABS hold solenoid other functional
C137C: Brake system voltage input out of range low
C137D: Brake system voltage input out of range high
C13BF: SM solenoid other functional
C13C2: SM1 solenoid circuit low
C13C3: SM1 solenoid circuit high
C13CB: SM2 solenoid circuit low
C13CC: SM2 solenoid circuit high
C143B: Brake system voltage solenoid relay stuck
C143C: Brake system voltage open circuit
All of the following conditions are met A, B, C, D, E, F, G and H
A. Command to solenoid relay On
B. Power supply for solenoid 9.5 V or more
C. +BS voltage 17.4 V or less
D. Following condition is met 0.120 seconds or more
Difference SRRH target current value (0.018 seconds before) and SRRH target current value Less than 0.022 A
E. Following condition is met 0.120 seconds or more
Difference SRLH target current value (0.018 seconds before) and SRLH target current value Less than 0.022 A
F. SRRH target current value SRLH target current value
G. SRRH target current value 0.25 A or more, and 1 A or less
H. SRLH target current value 0.25 A or more, and 1 A or less
C13BF

Monitor runs whenever the following DTCs are not stored C0597 (Case 1): ABS hold solenoid circuit stuck
C0597 (Case 2 to 5): ABS hold solenoid performance
C12A7: ABS hold solenoid (FL) circuit low
C12A8: ABS hold solenoid (FL) circuit high
C12B2: ABS release solenoid (FL) circuit low
C12B3: ABS release solenoid (FL) circuit high
C12BD: ABS hold solenoid (FR) circuit low
C12BE: ABS hold solenoid (FR) circuit high
C12C8: ABS release solenoid (FR) circuit low
C12C9: ABS release solenoid (FR) circuit high
C12D3: ABS hold solenoid (RL) circuit low
C12D4: ABS hold solenoid (RL) circuit high
C12DE: ABS release solenoid (RL) circuit low
C12DF: ABS release solenoid (RL) circuit high
C12E9: ABS hold solenoid (RR) circuit low
C12EA: ABS hold solenoid (RR) circuit high
C12F4: ABS release solenoid (RR) circuit low
C12F5: ABS release solenoid (RR) circuit high
C12F6: ABS hold solenoid other functional
C12F7: ABS hold solenoid other functional
C137C: Brake system voltage input out of range low
C137D: Brake system voltage input out of range high
C13C2: SM1 solenoid circuit low
C13C3: SM1 solenoid circuit high
C13CB: SM2 solenoid circuit low
C13CC: SM2 solenoid circuit high
C143B: Brake system voltage solenoid relay stuck
C143C: Brake system voltage open circuit
All of the following conditions are met A, B, C, D, E, F, G and H
A. Command to solenoid relay On
B. Power supply for solenoid 9.5 V or more
C. +BS voltage 17.4 V or less
D. Following condition is met 0.240 seconds or more
Difference SM1 target current value (0.018 seconds before) and SM1 target current value Less than 0.022 A
E. Following condition is met 0.240 seconds or more
Difference SM2 target current value (0.018 seconds before) and SM2 target current value Less than 0.022 A
F. SM1 target current value SM2 target current value
G. SM1 target current value 0.348 A or more, and 0.568 A or less
H. SM2 target current value 0.348 A or more, and 0.568 A or less