Home >> Lexus >> 2023 >> NX 250 AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 87 (Engine Control System - Diagnostic Codes (P0010-P0069)) >> SFI System >> DTC P0010-01: Camshaft Position "A" Actuator Bank 1 General Electrical Failure [11/2021 - 03/2022] >> Monitor Description

Monitor Description

WARNING: This page is about a different car, the 2025 Lexus NX 350h, 2024 Lexus NX 350h, 2023 Lexus NX 350h, and 2022 Lexus NX 350h. However, it is still accessible from the selected car via links, so may be relevant.

This DTC is output when an IC overheat malfunction or an overcurrent malfunction is detected in the cam timing control motor with EDU assembly. The cam timing control motor with EDU assembly is equipped with a self diagnostic function, which is used to output diagnosis signals (VTM) to the ECM. If the ECM receives a motor driver interior malfunction signal, the ECM will illuminate the MIL and store this DTC.