DTC P0A94-9E: DC/DC Converter Stuck On; DTC P0D33-19: DC/DC Converter Circuit Current Above Threshold [11/2021 - ]: Procedure
- CHECK DTC OUTPUT
- Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes
Powertrain > Motor Generator > Trouble Codes
Powertrain > HV Battery > Trouble Codes
Result
Result Proceed to P0A94-9E or P0D33-19 only is output, or DTCs except the ones in the table below are also output. A DTCs of hybrid control system in the tables below are output. B DTCs of motor generator control system in the tables below are output. C DTCs of hybrid battery system in the tables below are output. D TABLE 1Malfunction Content System Relevant DTC Insulation malfunction Hybrid control system P1C7C-49 Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure P1C7D-49 Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure P1C7E-49 Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure P1C7F-49 Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure P1C80-49 Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure System main relay or high voltage circuit malfunction Hybrid control system P0AD9-11 Hybrid/EV Battery Positive Contactor Circuit Short to Ground P0AD9-15 Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open P0ADD-11 Hybrid/EV Battery Negative Contactor Circuit Short to Ground P0ADD-15 Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open P1C84-49 High Voltage Power Resource Circuit Short during Ready ON HV battery malfunction Hybrid control system P0A1F-94 Hybrid/EV Battery Energy Control Module Unexpected Operation P0ABF-00 Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance P0B23-1C Hybrid/EV Battery "A" Voltage Sensor Voltage Out of Range P31B3-00 Hybrid/EV Battery Voltage High U0111-87 Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message Hybrid battery system P0560-14 System Voltage (BATT) Circuit Short to Ground or Open P0606-29 Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Signal Invalid P0606-87 Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message P060A-47 Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure P060A-87 Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message P060B-16 Hybrid/EV Battery Energy Control Module A/D Processing Circuit Voltage Below Threshold P060B-49 Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure P0ABF-11 Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground P0ABF-15 Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open P0ABF-28 Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure P0ABF-2A Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range P0B0E-11 Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground P0B0E-15 Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open P0B13-62 Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure P0E2D-00 Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance P1A00-1C Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range P1A60-17 Hybrid/EV Battery Stack 2 Cell Circuit Voltage Above Threshold P1A61-16 Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold P1A81-00 Hybrid/EV Battery Stack 1 Delta SOC High (Extreme) P1A86-00 Hybrid/EV Battery Stack 2 Delta SOC High (Extreme) P1AFD-00 Flying Capacitor Circuit Voltage Out of Range P1AFD-1C Flying Capacitor/Internal Control Module Hybrid/EV Battery Monitor Voltage Out of Range P1CBB-12 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery P1CBB-14 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open P1CC8-1E Hybrid/EV Battery Stack 1 Voltage Difference Out of Range P1CC9-1E Hybrid/EV Battery Stack 2 Voltage Difference Out of Range P301A-1C Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range P31AA-17 Hybrid/EV Battery Stack 1 Cell Circuit Voltage Above Threshold P31AB-16 Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold P33DA-1E Hybrid/EV Battery Stack 1 Circuit Resistance Out of Range P33DB-1E Hybrid/EV Battery Stack 2 Circuit Resistance Out of Range P33E0-1B Hybrid/EV Battery Stack 1 Circuit Resistance Above Threshold P33E1-1B Hybrid/EV Battery Stack 2 Circuit Resistance Above Threshold P33EC-16 (Extreme) Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold P33ED-16 (Extreme) Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold U0293-87 Lost Communication with Hybrid/EV Powertrain Control Module Missing Message U1150-87 Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message TABLE 2Malfunction Content System Relevant DTC Microcomputer malfunction Motor generator control system P0A1A-47 Generator Control Module Watchdog / Safety MC Failure P0A1A-49 Generator Control Module Internal Electronic Failure P0A1B-1F Generator Control Module Circuit Intermittent P0A1C-47 Drive Motor "B" Control Module Watchdog / Safety MCU Failure P0A1C-49 Drive Motor "B" Control Module Internal Electronic Failure P1C2A-1C Generator A/D Converter Circuit Circuit Voltage Out of Range P1C2A-49 Generator A/D Converter Circuit Internal Electronic Failure P1C2A-71 Generator A/D Converter Circuit Actuator Stuck P1C2B-1C Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range P1C2B-49 Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure P1C2B-71 Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck P1C2C-1C Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range P1C2C-49 Drive Motor "B" Control Module AD Converter Internal Electronic Failure P1C2C-71 Drive Motor "B" Control Module A/D Converter Circuit Actuator Stuck P310A-83 Communication Error from Drive Motor "B" to Drive Motor "A" Value of Signal Protection Calculation Incorrect P310A-86 Communication Error from Drive Motor "B" to Drive Motor "A" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid P310A-87 Communication Error from Drive Motor "B" to Drive Motor "A" Missing Message P310B-83 Communication Error from Drive Motor "A" to Drive Motor "B" Value of Signal Protection Calculation Incorrect P310B-86 Communication Error from Drive Motor "A" to Drive Motor "B" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid P310B-87 Communication Error from Drive Motor "A" to Drive Motor "B" Missing Message P3133-83 Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect P3133-86 Communication Error from Generator to Drive Motor "A" Signal Invalid P3133-87 Communication Error from Generator to Drive Motor "A" Missing Message P3134-83 Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect P3134-86 Communication Error from Drive Motor "A" to Generator Signal Invalid P3134-87 Communication Error from Drive Motor "A" to Generator Missing Message P32BF-83 Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Value of Signal Protection Calculation Incorrect P32BF-86 Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid P32BF-87 Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Missing Message P32CF-83 Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Value of Signal Protection Calculation Incorrect P32CF-86 Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid P32CF-87 Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Missing Message Hybrid control system P0A1B-49 Drive Motor "A" Control Module Internal Electronic Failure Power source circuit malfunction Motor generator control system P06B0-1C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range P06D6-1C Generator Control Module Offset Power Circuit Voltage Out of Range P262C-1C Drive Motor "B" Control Module Offset Power Circuit Voltage Out of Range Communication malfunction Motor generator control system P3124-87 Lost Communication between Drive Motor "A" and HV/EV ECU Missing Message Hybrid control system P3123-87 Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message Sensor and actuator circuit malfunction Motor generator control system P0A3F-16 Drive Motor "A" Position Sensor Circuit Voltage Below Threshold P0A3F-21 Drive Motor "A" Position Sensor Signal Amplitude < Minimum P0A3F-22 Drive Motor "A" Position Sensor Signal Amplitude > Maximum P0A45-16 Drive Motor "B" Position Sensor Circuit Voltage Below Threshold P0A45-21 Drive Motor "B" Position Sensor Signal Amplitude < Minimum P0A45-22 Drive Motor "B" Position Sensor Signal Amplitude > Maximum P0A4B-16 Generator Position Sensor Circuit Voltage Below Threshold P0A4B-21 Generator Position Sensor Signal Amplitude < Minimum P0A4B-22 Generator Position Sensor Signal Amplitude > Maximum P0A60-12 Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery P0A60-14 Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open P0A60-1C Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range P0A63-12 Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery P0A63-14 Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open P0A63-1C Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range P0A69-12 Drive Motor "B" Phase V Current (High Resolution) Circuit Short to Battery P0A69-14 Drive Motor "B" Phase V Current (High Resolution) Circuit Short to Ground or Open P0A69-1C Drive Motor "B" Phase V Current (High Resolution) Circuit Voltage Out of Range P0A6C-12 Drive Motor "B" Phase W Current (High Resolution) Circuit Short to Battery P0A6C-14 Drive Motor "B" Phase W Current (High Resolution) Circuit Short to Ground or Open P0A6C-1C Drive Motor "B" Phase W Current (High Resolution) Circuit Voltage Out of Range P0BE5-12 Drive Motor "A" Phase U Current Sensor Circuit Short to Battery P0BE5-14 Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open P0BE5-28 Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure P0BE9-12 Drive Motor "A" Phase V Current Sensor Circuit Short to Battery P0BE9-14 Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open P0BE9-28 Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure P0BED-12 Drive Motor "A" Phase W Current Sensor Circuit Short to Battery P0BED-14 Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open P0BED-28 Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure P0BF1-12 Drive Motor "B" Phase U Current Sensor Circuit Short to Battery P0BF1-14 Drive Motor "B" Phase U Current Sensor Circuit Short to Ground or Open P0BF1-28 Drive Motor "B" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure P0BF5-12 Drive Motor "B" Phase V Current Sensor Circuit Short to Battery P0BF5-14 Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open P0BF5-28 Drive Motor "B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure P0BF9-12 Drive Motor "B" Phase W Current Sensor Circuit Short to Battery P0BF9-14 Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open P0BF9-28 Drive Motor "B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure P0BFD-62 Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure P0BFE-62 Drive Motor "B" Phase U-V-W Current Sensor Signal Compare Failure P0C50-13 Drive Motor "A" Position Sensor Circuit "A" Circuit Open P0C50-16 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold P0C50-17 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold P0C55-13 Drive Motor "B" Position Sensor Circuit "A" Circuit Open P0C55-16 Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Below Threshold P0C55-17 Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Above Threshold P0C5A-13 Drive Motor "A" Position Sensor Circuit "B" Circuit Open P0C5A-16 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold P0C5A-17 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold P0C5F-13 Drive Motor "B" Position Sensor Circuit "B" Circuit Open P0C5F-16 Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Below Threshold P0C5F-17 Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Above Threshold P0C64-13 Generator Position Sensor Circuit "A" Circuit Open P0C64-16 Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold P0C64-17 Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold P0C69-13 Generator Position Sensor Circuit "B" Circuit Open P0C69-16 Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold P0C69-17 Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold P0D2D-16 Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold P0D2D-17 Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold P0DFA-62 Generator Phase U-V-W Current Sensor Signal Compare Failure P0E00-12 Generator Phase U Current Sensor Circuit Short to Battery P0E00-14 Generator Phase U Current Sensor Circuit Short to Ground or Open P0E00-28 Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure P0E04-12 Generator Phase V Current Sensor Circuit Short to Battery P0E04-14 Generator Phase V Current Sensor Circuit Short to Ground or Open P0E04-28 Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure P0E08-12 Generator Phase W Current Sensor Circuit Short to Battery P0E08-14 Generator Phase W Current Sensor Circuit Short to Ground or Open P0E08-28 Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure P0E31-16 DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold P0E31-17 DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold P0E51-11 DC/DC Converter Current Sensor Circuit Short to Ground P0E51-15 DC/DC Converter Current Sensor Circuit Short to Battery or Open P0E51-28 DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure P1CAC-49 Generator Position Sensor Internal Electronic Failure P1CAD-49 Drive Motor "A" Position Sensor Internal Electronic Failure P1CAE-49 Drive Motor "B" Position Sensor Internal Electronic Failure P1CAF-38 Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect P1CB0-38 Drive Motor "A" Position Sensor REF Signal Frequency Incorrect P1CB1-38 Drive Motor "B" Position Sensor REF Signal Frequency Incorrect Hybrid control system P0C76-00 Hybrid/EV Battery System Discharge Time Too Long P0D2D-1C Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range P0E31-1C Boosting Converter Voltage Sensor "A" Voltage Out of Range System malfunction Motor generator control system P0A90-00 Drive Motor "A" Performance P0A91-00 Drive Motor "B" Performance P0A92-00 Hybrid/EV Generator Performance P0BFF-1D Drive Motor "A" Circuit Current Out of Range P0C02-1D Drive Motor "B" System Circuit Current Out of Range P0C19-00 Drive Motor "A" Execution Torque Performance P0C1A-00 Drive Motor "B" Execution Torque Performance P0CA3-00 DC/DC Converter Step Up Voltage Performance P0E71-00 Generator Execution Torque Performance P1CA5-1D Hybrid/EV Generator Circuit Current Out of Range P314F-1F DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent P3153-1D DC/DC Converter Current Sensor Circuit Current Out of Range Hybrid control system P0A93-00 Inverter "A" Cooling System Performance P0AA6-49 Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure P0C73-96 Motor Electronics Coolant Pump "A" Component Internal Failure P314A-31 Motor Electronics Coolant Pump "A" No Signal TABLE 3System Relevant DTC Motor generator control system P0A3F-1F Drive Motor "A" Position Sensor Circuit Intermittent P0A45-1F Drive Motor "B" Position Sensor Circuit Intermittent P0A4B-1F Generator Position Sensor Circuit Intermittent P0A60-1F Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent P0A63-1F Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent P0A69-1F Drive Motor "B" Phase V Current (High Resolution) Circuit Intermittent P0A6C-1F Drive Motor "B" Phase W Current (High Resolution) Circuit Intermittent P0BE5-1F Drive Motor "A" Phase U Current Sensor Circuit Intermittent P0BE9-1F Drive Motor "A" Phase V Current Sensor Circuit Intermittent P0BED-1F Drive Motor "A" Phase W Current Sensor Circuit Intermittent P0C50-1F Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent P0C55-1F Drive Motor "B" Position Sensor Circuit "A" Circuit Intermittent P0C5A-1F Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent P0C5F-1F Drive Motor "B" Position Sensor Circuit "B" Circuit Intermittent P0C64-1F Generator Position Sensor Circuit "A" Circuit Intermittent P0C69-1F Generator Position Sensor Circuit "B" Circuit Intermittent P0D2D-1F Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent P0E00-1F Generator Phase U Current Sensor Circuit Intermittent P0E04-1F Generator Phase V Current Sensor Circuit Intermittent P0E08-1F Generator Phase W Current Sensor Circuit Intermittent P0E31-1F DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent P0E51-1F DC/DC Converter Current Sensor Circuit Intermittent P1C60-1F Generator Control Module Position Sensor REF Power Source Circuit Intermittent P1C62-1F Generator Control Module Offset Power Circuit Intermittent P1C63-1F Drive Motor "B" Control Module Offset Power Circuit Intermittent P1C64-1F Generator Control Module Circuit Intermittent P1C65-1F Generator Control Module Circuit Intermittent P1C66-1F Drive Motor "B" Control Module Circuit Intermittent P1C67-1F Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent P1C68-1F Drive Motor "B" Phase U-V-W Current Sensor Circuit Intermittent P1C69-1F Generator Phase U-V-W Current Sensor Circuit Intermittent P3124-1F Lost Communication between Drive Motor "A" and HV/EV ECU Circuit Intermittent HINT:
- P0A94-9E or P0D33-19 may be output as a result of the malfunction indicated by the DTCs above.
- The chart above is listed in inspection order of priority.
- Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
- If DTC P0A94-9E is output, replace the inverter with converter assembly after completing repairs.
- P0A94-9E or P0D33-19 may be output as a result of the malfunction indicated by the DTCs above.
- Turn the ignition switch off.
Result:
B
GO TO DTC CHART (HYBRID CONTROL SYSTEM)
Refer to DIAGNOSTIC TROUBLE CODE CHART [11/2021 - 03/2024] , or refer to DIAGNOSTIC TROUBLE CODE CHART [03/2024 - ]
Result:
C
GO TO DTC CHART. Refer to DIAGNOSTIC TROUBLE CODE CHART [11/2021 - ]
Result:
D
GO TO DTC CHART (HYBRID BATTERY SYSTEM)
Refer to DIAGNOSTIC TROUBLE CODE CHART [11/2021 - ]
Result:
A
See step 2
- Check for DTCs.
- CHECK FREEZE FRAME DATA AND DIAGNOSIS RELATED INFORMATION
- Read the diagnosis related information and freeze frame data of DTC P0A94-9E or P0D33-19.
Powertrain > Motor Generator > Utility
Tester Display Diagnosis Related Information Powertrain > Motor Generator > Trouble Codes
Result
Result Proceed to DTC P3124-87 is listed in Diagnosis Related Information. A DTC P3124-87 is not listed in Diagnosis Related Information and the value of freeze frame data item Emergency Shutdown Signal is ON. B Other than above C - Turn the ignition switch off.
Result:
A
GO TO DTC CHART (P3124-87)
Result:
B
GO TO DTC CHART (P321E-9F)
Refer to DTC P321E-9F: Motor/Generator Shutdown Signal Stuck Off [11/2021 - ]
Result:
C
See step 3
- Read the diagnosis related information and freeze frame data of DTC P0A94-9E or P0D33-19.
- CHECK FREEZE FRAME DATA
- Read the freeze frame data of DTC P0A94-9E or P0D33-19.
Powertrain > Motor Generator > Trouble Codes
Result
Result Proceed to Boosting Converter Temperature (Upper) and Boosting Converter Temperature 1 (Lower) are 120°C or more A Other than above B - Turn the ignition switch off.
Result:
B
See step 5
Result:
A
See step 4
- Read the freeze frame data of DTC P0A94-9E or P0D33-19.
- CHECK COOLING SYSTEM
Refer to Cooling System [11/2021 - 03/2023] , or refer to Cooling System [03/2023 - ]
Result
Proceed to NEXT Result:
NEXT
See step 5
- CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Refer to PROCEDURE - Step 3
Result
Result Proceed to OK A NG (The connector is not connected securely.) B NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C Result:
B
CONNECT SECURELY
Result:
C
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
A
See step 6
- CHECK GENERATOR RESOLVER CIRCUIT
Refer to Generator Resolver Circuit [11/2021 - ]
Result
Proceed to NEXT Result:
NEXT
See step 7
- CHECK MOTOR RESOLVER CIRCUIT
Refer to Motor Resolver Circuit [11/2021 - ]
Result
Proceed to NEXT Result:
NEXT
See step 8
- CHECK REAR MOTOR RESOLVER CIRCUIT
Refer to Rear Motor Resolver Circuit [11/2021 - ]
Result
Proceed to NEXT Result:
NEXT
See step 9
- CHECK GENERATOR HIGH-VOLTAGE CIRCUIT
Refer to Generator High-voltage Circuit [11/2021 - ]
Result
Proceed to NEXT Result:
NEXT
See step 10
- CHECK MOTOR HIGH-VOLTAGE CIRCUIT
Refer to Motor High-voltage Circuit [11/2021 - ]
Result
Proceed to NEXT Result:
NEXT
See step 11
- CHECK REAR MOTOR HIGH-VOLTAGE CIRCUIT
Refer to Rear Motor High-voltage Circuit [11/2021 - 03/2024] , or refer to Rear Motor High-voltage Circuit [03/2024 - 12/2024] , or refer to Rear Motor High-voltage Circuit [12/2024 - ]
Result
Proceed to NEXT Result:
NEXT
See step 12
- CHECK INVERTER LOW-VOLTAGE CIRCUIT
Refer to Inverter Low-voltage Circuit [11/2021 - ]
HINT:
If the "Inverter Low-voltage Circuit" inspection results are normal, perform the next step.
Result
Proceed to NEXT Result:
NEXT
See step 13
- CHECK FREEZE FRAME DATA
- Read the freeze frame data for DTC P0A94-9E or DTC P0D33-19.NOTE:
As freeze frame data is stored immediately before and after a DTC is stored, make sure to only read the values for the moment the DTC was stored ("0(s)").
Result
Result Proceed to The value of Inverter Input Current is less than 50 A A The value of Inverter Input Current is 50 A or more B - Turn the ignition switch off.
Result:
A
REPLACE INVERTER WITH CONVERTER ASSEMBLY
Refer to REMOVAL [11/2021 - ]
Result:
B
REPLACE INVERTER WITH CONVERTER ASSEMBLY, NO. 2 TRACTION BATTERY DEVICE BOX ASSEMBLY and SERVICE PLUG GRIP
INVERTER WITH CONVERTER ASSEMBLY: Refer to REMOVAL [11/2021 - ]
NO. 2 TRACTION BATTERY DEVICE BOX ASSEMBLY: Refer to REMOVAL [11/2021 - ]
SERVICE PLUG GRIP: Refer to REMOVAL [11/2021 - ]
- Read the freeze frame data for DTC P0A94-9E or DTC P0D33-19.