DTC P0243-13: Turbocharger/Supercharger Wastegate Solenoid "A" Circuit Open [03/2023 - ]: Description
The waste gate valve is built into the turbine housing with valve sub-assembly and is operated by the vacuum regulating valve assembly. The ECM uses duty control to open and close the vacuum regulating valve assembly. The amount of opening is controlled according to the operation status.
When the engine is started, the degree of opening of the waste gate valve is optimally adjusted so that the hot combustion gases passing through it flow directly into the catalyst. In the low-engine-load operating range, the waste gate valve opens to lower the exhaust manifold pressure to reduce pumping losses and improve fuel economy. Closing the waste gate valve increases the torque in the engine low-speed, high-load range to improve response during acceleration.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Note |
|---|---|---|---|---|---|
| P0243-13 | Turbocharger/Supercharger Wastegate Solenoid "A" Circuit Open | Open or short in vacuum regulating valve assembly circuit for 1 second or more (1 trip detection logic) |
|
Comes on | SAE Code: P0243 |