Odo/Trip Switch Malfunction [12/2021 - ]: Procedure
- READ VALUE USING GTS (ODO/TRIP CHANGE SWITCH)
- Using the GTS, read the Data List.
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note ODO/TRIP Change Switch ODO/TRIP switch (Trip switch) OFF or ON OFF: ODO/TRIP switch (trip switch) released
ON: ODO/TRIP switch (trip switch) pushed- Body Electrical > Combination Meter > Data List
Tester Display ODO/TRIP Change Switch OK
ODO/TRIP switch condition displayed on the GTS changes with the actual switch operation.
Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [12/2021 - ]
Result:
NG
See step 2
- Using the GTS, read the Data List.
- INSPECT TRIP SWITCH
Refer to INSPECTION [12/2021 - ]
Result
Proceed to OK NG Result:
NG
REPLACE TRIP SWITCH. Refer to REMOVAL [12/2021 - ]
Result:
OK
See step 3
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - TRIP SWITCH)
- Disconnect the I5 combination meter assembly connector.
- Disconnect the I80 trip switch connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition I5-20 (ODO) - I80-4 (+) Always Below 1 Ω I5-19 (SW3) - I80-7 (E) Always Below 1 Ω I5-20 (ODO) or I80-4 (+) - Body ground Always 10 kΩ or higher I5-19 (SW3) or I80-7 (E) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [12/2021 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR