Entire Combination Meter does not Operate [12/2021 - ]: Procedure
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND)
- Disconnect the I5 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition I5-1 (EP) - Body ground Always Below 1 Ω I5-2 (ET) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition I5-6 (IG+) - Body ground Ignition switch off Below 1 V Ignition switch ON 11 to 14 V*1
10.5 to 16 V*2I5-5 (B) - Body ground Always 11 to 14 V - *1: w/o Stop and Start System
*2: w/ Stop and Start System
Result
Result Proceed to OK A NG (IG+ terminal) (w/ Stop and Start System) B NG (IG+ terminal) (w/o Stop and Start System) C NG (Other terminal) - *1: w/o Stop and Start System
Result:
A
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [12/2021 - ]
Result:
B
GO TO STOP AND START SYSTEM. Refer to Backup Boost Converter Circuit [12/2021 - 10/2023] , or refer to Backup Boost Converter Circuit [10/2023 - ]
Result:
C
REPAIR OR REPLACE HARNESS OR CONNECTOR