DTC B1501-13: Sub Fuel Sender Circuit Open [12/2021 - ]: Procedure
- INSPECT NO. 2 FUEL SENDER GAUGE ASSEMBLY
Refer to INSPECTION [12/2021 - ]
Result
Proceed to OK NG Result:
NG
REPLACE NO. 2 FUEL SENDER GAUGE ASSEMBLY. Refer to REMOVAL [12/2021 - ]
Result:
OK
See step 2
- INSPECT FUEL TANK VENT TUBE ASSEMBLY
Pre-procedure1
- Remove the fuel tank vent tube assembly.
Refer to REMOVAL [12/2021 - ]
Procedure1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A-1 (FV2) - B-1 Always Below 1 Ω A-2 (FE2) - B-2 Always Below 1 Ω A-3 (FR2) - B-3 Always Below 1 Ω Result
Proceed to OK NG Post-procedure1
- None
Result:
NG
REPLACE FUEL TANK VENT TUBE ASSEMBLY. Refer to REMOVAL [12/2021 - ]
Result:
OK
See step 3
- Remove the fuel tank vent tube assembly.
- CHECK HARNESS AND CONNECTOR (FUEL TANK VENT TUBE ASSEMBLY - COMBINATION METER ASSEMBLY)
Pre-procedure1
- Disconnect the V10 No. 2 fuel tank vent tube assembly connector.
- Disconnect the I5 combination meter assembly connector.
Procedure1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition V10-3 (FR2) - I5-8 (FR) Always Below 1 Ω V10-2 (FE2) - I5-34 (FE) Always Below 1 Ω V10-1 (FV2) - I5-24 (FV) Always Below 1 Ω I5-8 (FR) - Body ground Always 10 kΩ or higher I5-34 (FE) - Body ground Always 10 kΩ or higher I5-24 (FV) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG Post-procedure1
- None
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [12/2021 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR