Entire Combination Meter does not Operate [10/2015 - ]: Procedure
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Disconnect the J10 combination meter assembly connector.
- Measure the resistance according to the value (s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition J10-31 (ES) - Body ground Always Below 1 Ω J10-40 (EP) - Body ground Always Below 1 Ω - Measure the voltage according to the value (s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition J10-21 (IG+) - Body ground Power switch off Below 1 V Power switch on (IG) 11 to 14 V J10-22 (B) - Body ground Power switch off 11 to 14 V Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [10/2015 - 08/2016] , or refer to REMOVAL [08/2016 - 03/2018] , or refer to REMOVAL [03/2018 - 08/2019] , or refer to REMOVAL [08/2019 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR