Typical Enabling Conditions
WARNING: This page is about a different variant/trim than selected.
ALL
| The monitor will run whenever this DTC is not present. (Not circuit malfunction) |
P0717, P07BF, P07C0 (Turbine speed sensor circuit) P07C1, P07C2, P2767 (Input speed sensor circuit) P0793, P07C5, P07C6 (Intermediate shaft speed sensor circuit) P0335, P0337, P0338 (Crankshaft Position Sensor "A" circuit) (This condition applies only if using fail-safe) P0748 (Shift solenoid valve SL1 circuit) P0778 (Shift solenoid valve SL2 circuit) P0798 (Shift solenoid valve SL3 circuit) P2810 (Shift solenoid valve SL4 circuit) P2819 (Shift solenoid valve SL5 circuit) P0973, P0974 (Shift solenoid valve S1 circuit) P0115, P0117, P0118 (ECT sensor circuit) P0712, P0713 (ATF temperature sensor circuit (TFT sensor)) P0327, P0328, P032C, P032D, P0332, P0333, P033C, P033D (KCS sensor circuit) P0120, P0121, P0122, P0123, P0220, P0222, P0223, P0604, P0606, P0607, P060A, P060B, P060D, P060E, P0657, P1607, P2102, P2103, P2111, P2112, P2118, P2119, P2135 ((ETCS) Electronic throttle control system) U0100 (CAN communication system) |
| NSW switch | "D" and "not R" and "not N" |
| Duration time from shifting "N" to "D" | 4 sec. or more |
| ATF temperature | -10°C (14°F) or more |
| Engine | Starting |
| Fail-safe does not active due to following malfunctions: | |
| Shift solenoid valve SL1 | Not OFF or ON malfunction (P0746) |
| Shift solenoid valve SL2 | Not OFF or ON malfunction (P0776) |
| Shift solenoid valve SL3 | Not OFF or ON malfunction (P0796) |
| Shift solenoid valve SL4 | Not OFF or ON malfunction (P2808) |
| Shift solenoid valve SL5 | Not OFF or ON malfunction (P2817) |
| Shift solenoid valve S1 | Not OFF or ON malfunction (P0751, P0752) |
OFF MALFUNCTION (A)
| TCM indicated pressure value of SL1 | 1600 kPa (16.3 kgf/cm2 , 232 psi) or more |
| TCM selected gear | 1st |
| When either condition below is met: (a), (b), (c) or (d) | |
| (a) (1.46318 x Output speed - 0.55327 x Input speed) - 0.51283 x Turbine speed ((1.46318 x NO - 0.55327 x NC3) - 0.51283 x NT) |
-250 rpm or less |
| (b) (1.46318 x Output speed - 0.55327 x Input speed) - 0.51283 x Turbine speed ((1.46318 x NO - 0.55327 x NC3) - 0.51283 x NT) |
250 rpm or more |
| (c) (1.46318 x Output speed + 0.55327 x Input speed) - 0.51283 x Turbine speed ((1.46318 x NO + 0.55327 x NC3) - 0.51283 x NT) |
-250 rpm or less |
| (d) (1.46318 x Output speed + 0.55327 x Input speed) - 0.51283 x Turbine speed ((1.46318 x NO + 0.55327 x NC3) - 0.51283 x NT) |
250 rpm or more |
| Calculated load value | 7.75% or more |
| Throttle valve opening angle | 2% or more |
OFF MALFUNCTION (B)
| TCM indicated pressure value of SL1 | 1600 kPa (16.3 kgf/cm2 , 232 psi) or more |
| TCM selected gear | 2nd |
| Input speed (NC3) | 50 rpm or more |
| Calculated load value | 7.75% or more |
| Throttle valve opening angle | 2% or more |
OFF MALFUNCTION (C)
| TCM indicated pressure value of SL1 | 1600 kPa (16.3 kgf/cm2 , 232 psi) or more |
| TCM selected gear | 3rd |
| Turbine speed / Input speed (NT/NC3) | 1.9 or more and 2.0 or less |
| Calculated load value | 7.75% or more |
| Throttle valve opening angle | 2% or more |
OFF MALFUNCTION (D)
| TCM indicated pressure value of SL1 | 1600 kPa (16.3 kgf/cm2 , 232 psi) or more |
| TCM selected gear | 4th |
| Turbine speed / Input speed (NT/NC3) | 0.95 or more and 1.05 or less |
| Calculated load value | 7.75% or more |
| Throttle valve opening angle | 2% or more |
OFF MALFUNCTION (E)
| TCM indicated pressure value of SL1 | 300 kPa (3.1 kgf/cm2 , 44 psi) or more |
| TCM selected gear | 5th |
| When either condition below is met: (a), (b), (c) or (d) | |
| (a) (1.46318 x Output speed - 0.55327 x Input speed) - 0.51283 x Turbine speed ((1.46318 x NO - 0.55327 x NC3) - 0.51283 x NT) |
Less than -250 rpm |
| (b) (1.46318 x Output speed - 0.55327 x Input speed) - 0.51283 x Turbine speed ((1.46318 x NO - 0.55327 x NC3) - 0.51283 x NT) |
More than 250 rpm |
| (c) (1.46318 x Output speed + 0.55327 x Input speed) - 0.51283 x Turbine speed ((1.46318 x NO + 0.55327 x NC3) - 0.51283 x NT) |
Less than -250 rpm |
| (d) (1.46318 x Output speed + 0.55327 x Input speed) - 0.51283 x Turbine speed ((1.46318 x NO + 0.55327 x NC3) - 0.51283 x NT) |
More than 250 rpm |
| Calculated load value | 7.75% or more |
| Throttle valve opening angle | 2% or more |
OFF MALFUNCTION (F)
| TCM selected gear | 5th or less |
| When either condition below is met: (a), (b), (c), (d), (e) or (f) | |
| (a) Input Torque when TCM selected 1st | Specified value |
| (b) Input Torque when TCM selected 2nd | Specified value |
| (c) Input Torque when TCM selected 3rd | Specified value |
| (d) Input Torque when TCM selected 4th | Specified value |
| (e) Input Torque when TCM selected 5th | Specified value |
| (f) Time after following condition met | Less than 0.5 sec. |
| - Input Torque when TCM selected 1st | Specified value |
| - Input Torque when TCM selected 2nd | Specified value |
| - Input Torque when TCM selected 3rd | Specified value |
| - Input Torque when TCM selected 4th | Specified value |
| - Input Torque when TCM selected 5th | Specified value |
ON MALFUNCTION (A)
| TCM selected gear | 6th |
| Vehicle speed | 3 km/h (1.87 mph) or more |
| Throttle valve opening angle | 3% or more at engine speed 1000 rpm (conditions vary with engine speed) |
| Calculated load value | 7.75% or more |
| ECT | 40°C (104°F) or more |
| Spark advance from MAX. retard timing by KCS control | 0 °CA or more |
ON MALFUNCTION (B)
| TCM selected gear | 7th |
| Vehicle speed | 3 km/h (1.87 mph) or more |
| Throttle valve opening angle | 3% or more at engine speed 1000 rpm (conditions vary with engine speed) |
| Calculated load value | 7.75% or more |
| ECT | 40°C (104°F) or more |
| Spark advance from MAX. retard timing by KCS control | 0 °CA or more |
ON MALFUNCTION (C)
| TCM selected gear | 8th |
| Vehicle speed | 3 km/h (1.87 mph) or more |
| Throttle valve opening angle | 3% or more at engine speed 1000 rpm (conditions vary with engine speed) |
| Calculated load value | 7.75% or more |
| ECT | 40°C (104°F) or more |
| Spark advance from MAX. retard timing by KCS control | 0 °CA or more |
ON MALFUNCTION (D)
| TCM selected gear | 6th or more |