Inspection [09/2015 - ]: Procedure
- INSPECT SHIFT SOLENOID VALVE S1
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Shift Solenoid Valve S1)Standard Resistance
Tester Connection Condition Specified Condition Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body 20°C (68°F) 11 to 15 Ω If the result is not as specified, replace the shift solenoid valve S1.
- Connect a positive (+) lead from the battery to the terminal of the shift solenoid valve S1 connector and a negative (-) lead to the shift solenoid valve S1 body, and check that the shift solenoid valve S1 moves and makes an operating sound.NOTE:
When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.
OK
The shift solenoid valve S1 moves and makes an operating sound.
If the result is not as specified, replace the shift solenoid valve S1.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE S2
HINT:
Refer to Inspect Shift Solenoid Valve S1.
- INSPECT SHIFT SOLENOID VALVE SLU
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Shift Solenoid Valve SLU)Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω If the result is not as specified, replace the shift solenoid valve SLU.
- Connect a positive (+) lead from the battery with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the shift solenoid valve SLU connector, and check that the shift solenoid valve SLU moves and makes an operating sound.NOTE:
When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.
OK
The shift solenoid valve SLU moves and makes an operating sound.
If the result is not as specified, replace the shift solenoid valve SLU.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE SL1
HINT:
Refer to Inspect Shift Solenoid Valve SLU.
- INSPECT SHIFT SOLENOID VALVE SL2
HINT:
Refer to Inspect Shift Solenoid Valve SLU.
- INSPECT SHIFT SOLENOID VALVE SL3
HINT:
Refer to Inspect Shift Solenoid Valve SLU.
- INSPECT SHIFT SOLENOID VALVE SL4
HINT:
Refer to Inspect Shift Solenoid Valve SLU.
- INSPECT SHIFT SOLENOID VALVE SL5
HINT:
Refer to Inspect Shift Solenoid Valve SLU.
- INSPECT SHIFT SOLENOID VALVE SLT
HINT: