Switch Lights of Remote Touch do not Illuminate [09/2014 - 11/2017]: Procedure
- CHECK HARNESS AND CONNECTOR (ILLUMINATION SIGNAL)
- Disconnect the O76 remote operation controller assembly connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition O76-1 (ILL+) - Body ground Light control switch in tail or head position 11 to 14 V Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 2
- CHECK HARNESS AND CONNECTOR (REMOTE OPERATION CONTROLLER ASSEMBLY - COMBINATION METER ASSEMBLY)
- Disconnect the O76 remote operation controller assembly connector.
- Disconnect the O3 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition O76-8 (ILL-) - O3-39 (ILL-) Always Below 1 Ω O76-8 (ILL-) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 3
- REPLACE REMOTE OPERATION CONTROLLER ASSEMBLY
- Replace the remote operation controller assembly.
Refer to REMOVAL [09/2014 - ]
- Check if the switch illumination turns on.
OK
The switch illumination turns on when the light control switch is in the tail or head position.
Result
Proceed to OK NG
Result:
OK
END
Result:
NG
GO TO METER / GAUGE SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [09/2014 - ]
- Replace the remote operation controller assembly.