LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2022 >> NX 450h+ Base >> Repair and Diagnosis >> Brakes >> Mechanical - Hydraulic >> Electronically Controlled Brake System - Diagnostic Codes (6 Of 6) & Symptom Tests >> Electronically Controlled Brake System >> DTC P2530-00: Ignition Switch Run Position Malfunction [11/2021 - ] >> Typical Enabling Conditions

Typical Enabling Conditions

Monitor runs whenever the following DTCs are not stored C1021 (Case 1): Brake system voltage input out of range low
All of the following conditions are met -
IGR voltage 3.8 V or more
Communication status with hybrid control system Valid
IGP PT2 (CAN data) On