Typical Malfunction Thresholds
One of the following conditions is met: Condition (A), (B) or (C)
CONDITION (A)
| Target speed of transmission fluid pump motor - Measurement speed of transmission fluid pump motor | 800 rpm or more at transmission fluid temperature 40°C for more than 10 sec. (Conditions vary with transmission fluid temperature) |
CONDITION (B)
| One of the following conditions is met | 1, 2, 3, 4, or 5 |
| 1. Motor speed - Output speed x 1st gear ratio | 400 rpm or more |
| 2. Motor speed - (-Output speed x 1st gear ratio) l | 400 rpm or more |
| 3. Motor speed - Output speed x 2nd gear ratio | 400 rpm or more |
| 4. Motor speed - Output speed x 3rd gear ratio | 400 rpm or more |
| 5. Motor speed - Output speed x 4th gear ratio | 400 rpm or more |
CONDITION (C)
| One of the following conditions is met | 1, 2, 3, 4, 5, 6 or 7 |
| 1. Solenoid (SL1) valve | ON or OFF malfunction |
| 2. Solenoid (SL2) valve | OFF malfunction |
| 3. Solenoid (SL3) valve | OFF malfunction |
| 4. Solenoid (SL4) valve | ON or OFF malfunction |
| 5. Solenoid (SC1) valve | OFF malfunction |
| 6. Solenoid (SC2) valve | ON malfunction |
| 7. Solenoid (SLT) valve | ON malfunction |