Component Operating Range
C12A7 (CASE 1), C12B2 (CASE 1), C12BD (CASE 1), C12C8 (CASE 1), C12D3 (CASE 1), C12DE (CASE 1), C12E9 (CASE 1) AND C12F4 (CASE 1)
| Linear solenoid open circuit detection signal | Less than 3.91 V |
C12A7 (CASE 2 AND 3), C12B2 (CASE 2 AND 3), C12BD (CASE 2 AND 3), C12C8 (CASE 2 AND 3), C12D3 (CASE 2 AND 3), C12DE (CASE 2 AND 3), C12E9 (CASE 2 AND 3) AND C12F4 (CASE 2 AND 3)
| Experience of all of the following conditions are met | - |
| Linear solenoid current monitor value | Equal to or more 0.4 times the linear solenoid output duty |
| Linear solenoid current monitor value | 0.7 or less |
C12A8 (CASE 1), C12B3 (CASE 1), C12BE (CASE 1), C12C9 (CASE 1), C12D4 (CASE 1), C12DF (CASE 1), C12EA (CASE 1) AND C12F5 (CASE 1)
| Linear solenoid current monitor value | Less than 0.15 A |
C12A8 (CASE 2), C12B3 (CASE 2), C12BE (CASE 2), C12C9 (CASE 2), C12D4 (CASE 2), C12DF (CASE 2), C12EA (CASE 2) AND C12F5 (CASE 2)
| All of the following conditions are met | - |
| Main relay monitor | 3.5 V or more |
| Command to main relay | On |
| Linear solenoid output duty | 0% |
| Linear solenoid current monitor value | Less than 2.3 A |
C13CA AND C14F2
| Both of the following conditions are met | A and B |
| A. Experience of all of the following conditions are met | 0.012 seconds or more |
| Command to brake pressure control SMC solenoid | On |
| SMC solenoid monitor | Less than 4.13 V |
| B. Experience of all of the following conditions are met | 0.012 seconds or more |
| Command to brake pressure control SMC solenoid | Off |
| SMC solenoid monitor | Higher than 4.2 V |
C13CB AND C14F3
| SMC solenoid open circuit detection signal | Higher than 0.1 A |
C13CC (CASE 1) AND C14F4 (CASE 1)
| SMC solenoid leak detection signal | Higher than 11.25 V |
C13CC (CASE 2) AND C14F4 (CASE 2)
| SMC solenoid over current detection signal | Less than 2.3 A |