Typical Malfunction Thresholds
HINT:
SAE code only.
C0562
| Following conditions is met | 0.2 seconds or more |
| Brake pedal stroke sensor assembly power supply voltage | 4.67 V or less, or 5.41 V or more |
C124B
| One of the following conditions is met | - |
| Brake pedal stroke sensor 1 data invalid element | Invalid |
| Brake pedal stroke sensor 2 data invalid element | Invalid |
| Brake pedal stroke sensor assembly data | Invalid |
C1392
| Brake pedal stroke sensor zero point calibration value | Not stored |
P057C AND P05DD
| Both of the following conditions are met | 0.2 seconds or more |
| Brake pedal position sensor power supply voltage | Higher than 4.67 V, and less than 5.41 V |
| Power supply voltage ratio of SKS and VCSK | Less than 0.062 |
HINT:
The power supply voltage ratio is the ratio of the voltage of SKS and VCSK.
P057D AND P05DE
| Both of the following conditions are met | 0.2 seconds or more |
| Brake pedal position sensor power supply voltage | Higher than 4.67 V, and less than 5.41 V |
| Power supply voltage ratio of SKS and VCSK | Higher than 0.904 |
HINT:
The power supply voltage ratio is the ratio of the voltage of SKS and VCSK.
P057E AND P05DF
| Both of the following conditions are met | 0.2 seconds or more |
| Brake pedal position sensor power supply voltage | Higher than 4.67 V, and less than 5.41 V |
| Difference between the current power supply voltage ratio and the previous power supply voltage ratio of SKS and VCSK | Higher than 0.0848 |
HINT:
The power supply voltage ratio is the ratio of the voltage of SKS and VCSK.
P05E0
| Brake pedal stroke sensor assembly correlation state | Invalid |