Component Operating Range
HINT:
SAE code only.
C0562
| Following conditions is met | 0.2 seconds or more |
| Brake pedal stroke sensor assembly power supply voltage | Higher than 4.67 V, and less than 5.41 V |
C124B
| All of the following conditions are met | A, B, C and D |
| A. Either of the following conditions is met | 1 or 2 |
| 1. Both of the following conditions are met | - |
| Brake system voltage 1 | Higher than 8.5 V |
| Brake system voltage 1 monitor value | Valid |
| 2. Both of the following conditions are met | - |
| Brake system voltage 2 | Higher than 8.5 V |
| Brake system voltage 2 monitor value | Valid |
| B. Brake pedal stroke sensor 1 data invalid element | Valid |
| C. Brake pedal stroke sensor 2 data invalid element | Valid |
| D. Brake pedal stroke sensor assembly data | Valid |
C1392
| Brake pedal stroke sensor zero point calibration value | Stored |
P057C AND P05DD
| Both of the following conditions are met | 0.2 seconds or more |
| Brake pedal stroke sensor assembly power supply voltage | Higher than 4.67 V, and less than 5.41 V |
| Power supply voltage ratio of SKS and VCSK | 0.062 or more |
HINT:
The power supply voltage ratio is the ratio of the voltage of SKS and VCSK.
P057D AND P05DE
| Both of the following conditions are met | 0.2 seconds or more |
| Brake pedal stroke sensor assembly power supply voltage | Higher than 4.67 V, and less than 5.41 V |
| Power supply voltage ratio of SKS and VCSK | 0.904 or less |
HINT:
The power supply voltage ratio is the ratio of the voltage of SKS and VCSK.
P057E AND P05DF
| Both of the following conditions are met | 0.2 seconds or more |
| Brake pedal stroke sensor assembly power supply voltage | Higher than 4.67 V, and less than 5.41 V |
| Difference between the current power supply voltage ratio and the previous power supply voltage ratio of SKS and VCSK | 0.0636 or less |
HINT:
The power supply voltage ratio is the ratio of the voltage of SKS and VCSK.
P05E0
| All of the following conditions are met | - |
| Brake system voltage 1 | Higher than 8.5 V |
| Brake system voltage 1 monitor value | Valid |
| Brake system voltage 2 | Higher than 8.5 V |
| Brake system voltage 2 monitor value | Valid |
| Brake pedal stroke sensor assembly on experience (Low/Mid/High) | On |