DTC C13A6: Open or Short Circuit in Motor [10/2018 - 08/2021]: Procedure
- READ VALUE USING TECHSTREAM (PERMISSION OF RH INTERLOCKING PKB LOCK / PERMISSION OF LH INTERLOCKING PKB LOCK)
- Turn the power switch off.
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Chassis / Electric Parking Brake / Data List.
- Read the Data List according to the display on the Techstream.
Chassis > Electric Parking Brake > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Permission of RH Interlocking PKB Lock Parking brake actuator assembly RH parking brake lock control permission status OK or NG OK - Permission of LH Interlocking PKB Lock Parking brake actuator assembly LH parking brake lock control permission status OK or NG OK - Chassis > Electric Parking Brake > Data List
Tester Display Permission of RH Interlocking PKB Lock Permission of LH Interlocking PKB Lock Result
Proceed to NEXT
Result:
NEXT
See step 2
- INSPECT PARKING BRAKE WIRE ASSEMBLY
*a Front view of Parking Brake Wire Assembly *b (to wire harness connector) *c (to Parking Brake Actuator Assembly) *d for RH *e for LH - - - Remove the parking brake wire assembly.
- Check the parking brake wire assembly for damage.
OK
No damage.
HINT:
If damaged, there may be a short in the wire harness or a short to ground.
- Inspect the parking brake wire assembly.
Standard Resistance
FOR RHTester Connection Condition Specified Condition jN2-2 (MRR-) - j2-1 (-) Always Below 1 Ω jN2-2 (MRR-) - j2-2 (+) Always 10 kΩ or higher jN2-2 (MRR-) or j2-1 (-) - Body ground Always 10 kΩ or higher jN2-1 (MRR+) - j2-2 (+) Always Below 1 Ω jN2-1 (MRR+) - j2-1 (-) Always 10 kΩ or higher jN2-1 (MRR+) or j2-2 (+) - Body ground Always 10 kΩ or higher FOR LHTester Connection Condition Specified Condition kN2-2 (MRL-) - k2-1 (-) Always Below 1 Ω kN2-2 (MRL-) - k2-2 (+) Always 10 kΩ or higher kN2-2 (MRL-) or k2-1 (-) - Body ground Always 10 kΩ or higher kN2-1 (MRL+) - k2-2 (+) Always Below 1 Ω kN2-1 (MRL+) - k2-1 (-) Always 10 kΩ or higher kN2-1 (MRL+) or k2-2 (+) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPLACE PARKING BRAKE WIRE ASSEMBLY
Result:
OK
See step 3
- CHECK HARNESS AND CONNECTOR (PARKING BRAKE ECU (BRAKE ACTUATOR ASSEMBLY) - PARKING BRAKE ACTUATOR ASSEMBLY)
- Turn the power switch off.
- Make sure the parking brake wire assembly is securely installed.
- Disconnect the A48 parking brake ECU (brake actuator assembly) connector.
- Disconnect the j2 or k2 parking brake actuator assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
FOR RHTester Connection Condition Specified Condition A48-4 (MRR+) - j2-2 (+) Always Below 1 Ω A48-3 (MRR-) - j2-1 (-) Always Below 1 Ω A48-4 (MRR+) or j2-2 (+) - Body ground Always 10 kΩ or higher A48-3 (MRR-) or j2-1 (-) - Body ground Always 10 kΩ or higher FOR LHTester Connection Condition Specified Condition A48-7 (MRL+) - k2-2 (+) Always Below 1 Ω A48-8 (MRL-) - k2-1 (-) Always Below 1 Ω A48-7 (MRL+) or k2-2 (+) - Body ground Always 10 kΩ or higher A48-8 (MRL-) or k2-1 (-) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 4
- INSPECT PARKING BRAKE ACTUATOR ASSEMBLY
- Remove the parking brake actuator assembly.
Refer to REMOVAL [10/2018 - ]
- Inspect the parking brake actuator assembly.
Refer to INSPECTION [10/2018 - ]
Result
Proceed to OK NG
Result:
OK
REPLACE PARKING BRAKE ECU (BRAKE ACTUATOR ASSEMBLY). Refer to REMOVAL [10/2018 - 07/2022]
Result:
NG
REPLACE PARKING BRAKE ACTUATOR ASSEMBLY. Refer to REMOVAL [10/2018 - ]
- Remove the parking brake actuator assembly.