Entire Combination Meter does not Operate [10/2018 - ]: Procedure
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Disconnect the combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition F23-31 (ES) - Body ground Always Below 1 Ω F23-40 (EP) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
*a Component with harness connected
(Combination Meter Assembly)Standard Voltage
Tester Connection Switch Condition Specified Condition F23-21 (IG+) - Body ground Ignition switch off Below 1 V Ignition switch ON 11 to 14 V F23-22 (B) - Body ground Ignition switch off 11 to 14 V Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [10/2018 - 07/2022] Refer to REMOVAL [07/2022 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR