Blind Spot Monitor Sensor Communication Stop Mode [08/2021 - 07/2022]: Procedure
- CHECK FOR OPEN IN CAN BUS LINES (BLIND SPOT MONITOR SENSOR LH BRANCH LINE)
- Disconnect the cable from the negative (-) auxiliary battery terminal.
- Disconnect the blind spot monitor sensor LH connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Q4-2 (CA1P) - Q4-7 (CA1N) Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω *a Front view of wire harness connector
(to Blind Spot Monitor Sensor LH)Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE CAN BRANCH LINES OR CONNECTOR (BLIND SPOT MONITOR SENSOR LH)
Result:
OK
See step 2
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Q4-10 (BLGD) - Body ground Cable disconnected from negative (-) auxiliary battery terminal Below 1 Ω *a Front view of wire harness connector
(to Blind Spot Monitor Sensor LH) - Reconnect the cable to the negative (-) auxiliary battery terminal.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition Q4-5 (BLB) - Body ground Engine switch on (IG) 11 to 14 V Result
Proceed to OK NG
Result:
OK
REPLACE BLIND SPOT MONITOR SENSOR LH. Refer to REMOVAL [10/2018 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the resistance according to the value(s) in the table below.