Headup Display Communication Stop Mode [10/2018 - 07/2022]: Procedure
- CHECK FOR OPEN IN CAN BUS LINES (METER MIRROR SUB-ASSEMBLY BRANCH LINE)
- Disconnect the cable from the negative (-) auxiliary battery terminal.
- Disconnect the meter mirror sub-assembly connector.
- Measure the resistance according to the value(s) in the table below.
*a Front view of wire harness connector
(to Meter Mirror Sub-assembly)Standard Resistance
Tester Connection Condition Specified Condition F25-12 (MPX1) - F25-13 (MPX2) Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE CAN BRANCH LINES OR CONNECTOR (METER MIRROR SUB-ASSEMBLY)
Result:
OK
See step 2
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition F25-4 (ES) - Body ground Cable disconnected from negative (-) auxiliary battery terminal Below 1 Ω *a Front view of wire harness connector
(to Meter Mirror Sub-assembly) - Reconnect the cable to the negative (-) auxiliary battery terminal.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition F25-2 (B) - Body ground Always 11 to 14 V F25-1 (IG) - Body ground Engine switch on (IG) 11 to 14 V Result
Proceed to OK NG
Result:
OK
REPLACE METER MIRROR SUB-ASSEMBLY. Refer to REMOVAL [10/2018 - 07/2022]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the resistance according to the value(s) in the table below.