Inspection [10/2015 - ]: Procedure
- INSPECT TRIP SWITCH
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 5 (RV) - 7 (E) Light control rheostat up switch pressed Below 1 Ω Light control rheostat up switch not pressed 10 kΩ or higher 5 (RV) - 7 (E) Light control rheostat down switch pressed 1.71 to 1.89 kΩ Light control rheostat down switch not pressed 10 kΩ or higher 4 (A/B) - 7 (E) ODO/TRIP switch pressed Below 1 Ω ODO/TRIP switch not pressed 10 kΩ or higher If the result is not as specified, replace the trip switch.
*a Component without harness connected
(Trip Switch) *a Component without harness connected
(Trip Switch)Illumination Inspection
- Measure the resistance according to the value(s) in the table below.