SRS Warning Light does not Come ON [10/2014 - 05/2019]: Procedure
- CHECK AUXILIARY BATTERY
- Measure the auxiliary battery voltage with the power switch off.
Standard voltage
11 to 14 V
HINT:
It may be possible to tell whether the auxiliary battery is discharged by operating the horn.
If the voltage is below 11 V, recharge or replace the auxiliary battery before proceeding to the next step.
Result
Proceed to OK NG
Result:
NG
REPLACE OR RECHARGE AUXILIARY BATTERY
Result:
OK
See step 2
- Measure the auxiliary battery voltage with the power switch off.
- CHECK CONNECTION OF CONNECTOR
- Turn the power switch off.
- Disconnect the cable from the negative (-) auxiliary battery terminal, and wait for at least 90 seconds.
- Check that the connector is properly connected to the combination meter assembly.
Result
Proceed to The connector is properly connected The connector is not properly connected
Result:
The connector is not properly connected
CONNECT CONNECTORS PROPERLY
Result:
The connector is properly connected
See step 3
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND)
- Disconnect the connector from the combination meter assembly.
*a Front view of wire harness connector
(to Combination Meter Assembly) - Connect the cable to the negative (-) auxiliary battery terminal, and wait for at least 2 seconds.
- Turn the power switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition I10-21 (IG+) - Body ground Power switch on (IG) 11 to 14 V I10-22 (B) - Body ground Power switch off 11 to 14 V - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition I10-40 (EP) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 4
- Disconnect the connector from the combination meter assembly.
- CHECK SRS WARNING LIGHT (SHORT TO GROUND)
- Turn the power switch off.
- Disconnect the cable from the negative (-) auxiliary battery terminal, and wait for at least 90 seconds.
- Connect the connector to the combination meter assembly.
- Connect the cable to the negative (-) auxiliary battery terminal, and wait for at least 2 seconds.
- Turn the power switch on (IG).
- Check the SRS warning light condition.
OK
After the primary check period, the SRS warning light goes off for approximately 10 seconds and then remains on.
HINT:
The primary check period is approximately 6 seconds after the power switch is turned on (IG).
Result
Proceed to OK NG
Result:
OK
REPLACE AIRBAG ECU ASSEMBLY. Refer to REMOVAL [10/2014 - 05/2019]
Result:
NG
GO TO METER / GAUGE SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [10/2014 - ]