Automatic High Beam Switch Circuit [10/2014 - 09/2017]: Procedure
- READ VALUE USING TECHSTREAM (AUTO HIGH BEAM MAIN SWITCH)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Main Body / Data List.
- Read the display on the Techstream.
Body Electrical > Main Body > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Auto High Beam Main Switch Combination switch assembly (automatic high beam main switch) signal ON or OFF ON: Combination switch assembly (automatic high beam main switch) pressed
OFF: Combination switch assembly (automatic high beam main switch) not pressed- OK
Normal conditions listed above are displayed.
Result
Proceed to OK NG
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [10/2014 - 09/2017]
Result:
NG
See step 2
- INSPECT COMBINATION SWITCH ASSEMBLY
- Remove the combination switch assembly.
Refer to REMOVAL [10/2014 - ]
- Inspect the combination switch assembly.
Refer to INSPECTION [10/2014 - ]
Result
Proceed to OK NG
Result:
NG
REPLACE COMBINATION SWITCH ASSEMBLY. Refer to REMOVAL [10/2014 - 09/2017]
Result:
OK
See step 3
- Remove the combination switch assembly.
- CHECK HARNESS AND CONNECTOR (COMBINATION SWITCH ASSEMBLY - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) AND BODY GROUND)
- Disconnect the I33 combination switch assembly connector.
- Disconnect the I47 main body ECU (multiplex network body ECU) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition I33-1 (+B) - I47-23 (AHBI) Always Below 1 Ω I33-1 (+B) - Body ground Always 10 kΩ or higher I33-10 (E) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU). Refer to REMOVAL [10/2014 - 05/2019]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR