Odo/Trip Switch Malfunction [09/2015 - ]: Procedure
- READ VALUE USING TECHSTREAM (LIGHT CONTROL RHEOSTAT)
- Operate the Techstream according to the display and select the Data List.COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note ODO/TRIP Change SW ODO/TRIP switch condition/ON or OFF ON: ODO/TRIP switch pushed
OFF: ODO/TRIP switch not pushed- OK
Switch condition (ON/OFF) can be switched by actual operation.
Result:
NG
REPLACE COMBINATION METER ASSEMBLY
Refer to REMOVAL [09/2015 - ] )
Result:
OK
See step 2
- Operate the Techstream according to the display and select the Data List.
- INSPECT LIGHT CONTROL RHEOSTAT (ODO/TRIP SWITCH)
- Remove the light control rheostat. Refer to REMOVAL [09/2015 - ] ).
- Inspect the light control rheostat. Refer to INSPECTION [09/2015 - ] ).
Result:
NG
REPLACE LIGHT CONTROL RHEOSTAT
Refer to REMOVAL [09/2015 - ] )
Result:
OK
See step 3
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - LIGHT CONTROL RHEOSTAT)
- Disconnect the E10 combination meter assembly connector.
- Disconnect the E9 light control rheostat connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition E120-8 (RSET) - E9-4 (A/B) Always Below 1 Ω E120-19 (E2) - E9-1 (E) Always Below 1 Ω E120-8 (RSET) or E9-4 (A/B) - Body ground Always 10 kΩ or higher
Result:
OK
REPLACE COMBINATION METER ASSEMBLY
Refer to REMOVAL [09/2015 - ] )
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR