Meter Illumination is Always Dark [09/2015 - ]: Procedure
- CHECK CAN COMMUNICATION SYSTEM
- Check for DTCs. Refer to DTC CHECK / CLEAR [09/2015 - ]
).RESULT
Result Proceed to DTC is not output A CAN communication system DTC is output B Lighting system DTC (B1244) is output C
Result:
B
GO TO CAN COMMUNICATION SYSTEM
Refer to HOW TO PROCEED WITH TROUBLESHOOTING [09/2015 - 08/2020] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2020 - ] )
Result:
C
GO TO LIGHTING SYSTEM
Refer to PRECAUTION [09/2015 - ] )
Result:
A
See step 2
- Check for DTCs. Refer to DTC CHECK / CLEAR [09/2015 - ]
).
- PERFORM ACTIVE TEST USING TECHSTREAM (DIMMER SWITCH)
- Operate the Techstream according to the display and select the Active Test.MAIN BODY
Tester Display Test Part Control Range Diagnostic Note Dimmer Signal Illumination dimming operation ON or OFF - OK
Meter illumination is dimmed when the dimmer switch is on and the Active Test "Dimmer Signal" is ON.
HINT:
Refer to the sensitivity setting in the customization table of the automatic light control system. Refer to CUSTOMIZE PARAMETERS [09/2015 - ] ).
Result:
OK
CHECK LIGHTING SETTING
Refer to PRECAUTION [09/2015 - ] )
Result:
NG
See step 3
- Operate the Techstream according to the display and select the Active Test.
- REPLACE COMBINATION METER ASSEMBLY
- Temporarily replace the combination meter with a new one. Refer to REMOVAL [09/2015 - ] ).
Result:
NEXT
See step 4
- CHECK COMBINATION METER ASSEMBLY
- Check that the operation of the combination meter returns to normal. Refer to REMOVAL [09/2015 - ]
).
OK
Operation of combination meter returns to normal.
Result:
OK
END (COMBINATION METER IS DEFECTIVE)
Result:
NG
REPLACE MAIN BODY ECU (COWL SIDE JUNCTION BLOCK LH) Removal [09/2015 - ] and Installation [09/2015 - ]
- Check that the operation of the combination meter returns to normal. Refer to REMOVAL [09/2015 - ]
).