DTC B1500: Fuel Sender Open Detected [09/2015 - ]: Procedure
- READ VALUE USING TECHSTREAM (FUEL SENDER GAUGE)
- Operate the Techstream according to the display and select the Data List. Refer to DATA LIST / ACTIVE TEST [09/2015 - 08/2017]
, or refer to DATA LIST / ACTIVE TEST [08/2017 - ]
).COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Fuel Input Fuel sender gauge (main) input signal/Min.: 0, Max.: 127.5 Fuel receiver gauge indicates F: 83.7 L
Fuel receiver gauge indicates 3/4: 66.5 L
Fuel receiver gauge indicates 1/2: 49.5 L
Fuel receiver gauge indicates 1/4: 31.2 L
Fuel receiver gauge indicates E: 12.5 LUnit: L OK
Fuel amount value displayed on the Techstream is almost the same as needle indication.
Result:
OK
REPLACE COMBINATION METER ASSEMBLY
Refer to REMOVAL [09/2015 - ] )
Result:
NG
See step 2
- Operate the Techstream according to the display and select the Data List. Refer to DATA LIST / ACTIVE TEST [09/2015 - 08/2017]
, or refer to DATA LIST / ACTIVE TEST [08/2017 - ]
).
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - PUMP AND GAUGE AND BODY GROUND)
- Disconnect the N120 combination meter assembly connector.
- Disconnect the N1 fuel suction with pump and gauge tube assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition N120-33 (FR) - N1-3 (FR) Always Below 1 Ω N120-35 (FV) - N1-1 (FV) Always Below 1 Ω N120-17 (FE&B) - N1-2 (FE) Always Below 1 Ω N120-33 (FR) or N1-3 (FR) - Body ground Always 10 kΩ or higher N120-35 (FV) or N1-1 (FV) - Body ground Always 10 kΩ or higher N120-17 (FE&B) or N1-2 (FE) - Body ground Always 10 kΩ or higher
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 3
- INSPECT FUEL SUCTION WITH PUMP AND GAUGE TUBE ASSEMBLY
- Remove the fuel sender gauge assembly. Refer to REMOVAL [09/2015 - ]
).
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A-2 (FS) - B-2 (FS) Always Below 1 Ω A-3 (FE) - B-1 (FE) Always Below 1 Ω TEXT IN ILLUSTRATION* a Component without harness connected
(Fuel Suction with Pump and Gauge Tube Assembly)* b Component without harness connected
(Fuel Sender Gauge Assembly)*c Connector A *d Connector B
Result:
NG
REPLACE FUEL SUCTION WITH PUMP AND GAUGE TUBE ASSEMBLY
Refer to REMOVAL [09/2015 - ] )
Result:
OK
See step 4
- Remove the fuel sender gauge assembly. Refer to REMOVAL [09/2015 - ]
).
- INSPECT FUEL SENDER GAUGE ASSEMBLY
- Remove the fuel sender gauge assembly. Refer to REMOVAL [09/2015 - ] ).
- Inspect the fuel sender gauge assembly. Refer to PROCEDURE - Step 1 ).
Result:
OK
REPLACE COMBINATION METER ASSEMBLY
Refer to REMOVAL [09/2015 - ] )
Result:
NG
REPLACE FUEL SENDER GAUGE ASSEMBLY
Refer to REMOVAL [09/2015 - ] )